14. Use the following connection cables:

Primary side (230 VAC)
Secondary side (24 VDC)

15. Adjusting the output voltage

The output voltage can be set externally between
22.8 V DC and 26.4 V DC on the trim potentiometer.
Caution!
If the factory-set output voltage of 24.00 V DC is changed, any warranty of all
connected A3000 open components will be voided!

16. Short-circuit and overload behaviour

In the event of a short circuit in mains operation, the output remains enabled.
The voltage thresholds mentioned for switching on and off after a short circuit only
apply after the voltage on the primary side has been disconnected or the voltage
threshold of 24V has been reached again.

17. Parallel connectivity

These power supplies can be connected in parallel. This only applies to device that
have been factory-adjusted to 24.00 V DC.

18. Fuses

Caution!
The system power supply is internally protected on the primary side with a
2 AT/250 V fuse. If this fuse blows, there is a high probability that the unit is
defective.
Only use suitable installation cables according to
VDE (e.g. NYM 3×1.5 mm²).
For AQUA3000open applications, only use
original system lines.
For other 24VDC applications, use a suitable
installation cable (min. NYM 2x0.5 mm²).
System cable for continuous use in water,
Halogen-free 100 m. . . . . . . . . . . 2000104272
Halogen-free 25 m. . . . . . . . . . . . 2000104274
System cable,
Not halogen-free 100 m. . . . . . . . 2000100801
Not halogen-free 25 m. . . . . . . . . 2000100852
- 8 -