Basic Operation

Indicator Lights

All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on.
"LINE POWER" LED: this green LED lights continuously to indicate
that the UPS is ON and supplying your equipment with AC power from a
utility source. The LED flashes to remind you that you have used the
ON/OFF button to place the UPS in "Charge-Only" mode.
"BATTERY POWER" LED: this yellow LED flashes and an alarm
sounds (4 short beeps followed by a pause) to indicate the UPS is operating
from its internal batteries. During a prolonged brownout or blackout, this
LED and the "REPLACE BATTERY" LED will light continuously and an
alarm will sound continuously to indicate the UPS's batteries are nearly out
of power; you should save files and shut down your equipment immediately.
"REPLACE BATTERY" LED: this red LED lights continuously and an
alarm sounds after a self-test to indicate the UPS batteries need to be
recharged or replaced. Allow the UPS to recharge continuously for 12
hours, and repeat the self-test. If the LED continues to flash, contact Tripp Lite
for service. If your UPS requires battery replacement, visit
www.tripplite.com/support/battery/index.cfm to locate the specific Tripp Lite
replacement battery for your UPS.
"OVERLOAD" LED: this red LED lights continuously and an alarm
sounds after a self-test to indicate the battery-supported outlets are overloaded.
To clear the overload, unplug some of your equipment from the battery-
supported outlets and run the self-test repeatedly until the LED is no longer
lit and the alarm is no longer sounding.
CAUTION! Any overload that is not corrected by the user immediately
following a self-test may cause the UPS to shut down and cease supplying
output power in the event of a blackout or brownout.
"VOLTAGE CORRECTION" LED (select models only): Lights green
whenever your UPS is automatically correcting high or low AC line voltage.
The UPS will also click gently. These are normal, automatic operations of
your UPS, and no action is required on your part.
Other UPS Features
NORM
DELAY
A
A
B
OMNIVS800 shown
NORM
DELAY
A
A
B
OMNIVS1000 shown
continued
AC Outlets: the
A
outlets will provide battery backup and surge protection;
plug your computer, monitor and other critical devices here. The
will provide surge protection only; plug your printer and other non-essential
devices here. Your UPS is designed to only support computer equipment.
You will overload the UPS if the total VA ratings for all the equipment you
connect to the
A
Specifications). If you are unsure if you have overloaded the
a self-test (see "MUTE/TEST" Button description).
NORM
DELAY
A
A
B
OMNIVS1500XL shown
outlets exceeds the UPS's Output Capacity (see
6
outlets
B
outlets, run
A