Lock Function - Weller WR 2 Traducción Del Manual Original

Ocultar thumbs Ver también para WR 2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Parameter menu

lock function

After the lock has been activated, only the
following buttons on the soldering station are
enabled:
WR 2: ┌ 1 ┐, ┌1·2┐,┌ 2 ┐, ECO , AIR
WR 3M: ┌ 1 ┐, ┌ 2 ┐, ┌ 3 ┐ ┌1·2·3┐, Pick Up , AIR
All other settings are disabled until the repair
station is unlocked again.
Notice
If you want only one temperature value to be
selectable, the control keys fixed temperature
keys) must be set to the same temperature value.
Locking the soldering station
Select menu option. „OFF" appears on the display.
The key symbol is flashing.
Set the desired three-digit locking code (between
001 and 999) using the UP / DOWN buttons.
WR 2: Press button ┌ 2 ┐ for 5 seconds.
Pressure gauge threshold (LEVEL)
This function can be used to define the mainte-
nance interval of the desoldering tool. This is done
by setting the value in mbar at which the electric
pressure gauge issues a warning signal when the
intake system is contaminated (LED of the vacuum
pump switches from green to red). The set value is
dependent on the suction nozzles used.
Adjustable
-400 mbar to -800 mbar
factory setting
-600 mbar
1. The system (tips and filter) must be free.
Station code (Remote ID)
WR 3M
A station code (Remote ID) can be assigned to
each station, allowing the station to be clearly
identified via the USB port.
46
WR 3M: Press button ┌ 3 ┐ for 5 seconds.
The code is stored.
The key symbol is displayed. The lock is active.
The display switches to the main menu.
Unlocking the soldering station
1. Select menu option. „ON" appears on the dis-
play. The key symbol is displayed.
2. Set the three-digit locking code using the
UP / DOWN buttons.
3. WR 2: Press button ┌ 2 ┐ .
WR 3M: Press button ┌ 3 ┐ .
4. The station is now unlocked. The display swit-
ches to the main menu.
Forgotten code?
Please contact our Customer Service:
technical-service@weller-tools.com
2. Select the menu item „Pressure gauge
threshold" in the menu.
3. Set the „Pressure gauge threshold" pressure
value with the UP or DOWN button. The status
LED switches back and forth between red and
green. Use the UP button to increase vacuum
by 50 to 80 mbar, then pinch the vacuum tube
and check whether the LED switches from
green to red.
Option
Description
0-999
Individually adjustable
Menu access
- 1 -
Menu access
- 2 -
Menu access
- 2 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wr 3m

Tabla de contenido