Section 4
Parts Removal for Cleaning/Sanitizing
Single Evaporator Ice Machines
A. Remove the water curtain
• Gently flex the curtain in the center and
remove it from the right side.
• Slide the left pin out.
B. Remove the water trough
• Depress tabs on right and left side of the
water trough.
• Allow front of water trough to drop as
you pull forward to disengage the rear
pins.
C. Remove the ice thickness and harvest
float switches
• Pull the float switch straight down to
disengage.
• Lower the float switch until the wiring
connector is visible.
• Disconnect the wire lead from the float
switch.
• Remove the float switch from the ice
machine.
A
Part Number: 000014142 Rev 02 5/17
D. Remove the water distribution tube
NOTE: Distribution tube thumbscrews
are retained to prevent loss. Loosen
thumbscrews but do not pull thumbscrews
out of distribution tube.
• Loosen the two outer screws (do not
remove screws completely they are
retained to prevent loss) and pull
forward on the distribution tube to
release from slip joint.
• Disassemble distribution tube
by loosening the two (2) middle
thumbscrews and dividing the
distribution tube into two pieces.
• Proceed to page 31 Step 6.
Maintenance
D
C
B
33