Electric Heating 2 Kw (Additional Equipment) - HOESCH Reviva Instrucciones De Montaje Y Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
07

Electric heating 2 kW (additional equipment)

After switching the electric water heater 2 kW on, the rotating water massage nozzle is switched on automatically. The bath
water temperature is maintained at the constant level of approx. 37°C.
EL2
GB
EH2
STB
2. Connection
socket
In case of a version with integrated electric heating 2 kW the system is factory-equipped with an electric part and control
components. In such a situation a separate electric connection should be made for part of the heating power and it should
be protected separately 10 A.
Ensure polarity according to the connections diagram. Connection to the power supply system and operation of
the system only with the protection cable and connected equalizing of potentials. The power supply connection of
the system control unit and for part of the heating power should be protected with a common current trip device
30mA.
24
N
PE
L
1 3 5 7 A1
PE
K 1
2 4 6 8 A2
Electric heater
Overheating
limit control
Flow
11
switch
Flow
3
12
1
1
2
Thermostat 37°C Fixed value
10 A
HAW2
Whirl / Air
L
N
PE
connection socket, made by
the construction team
2 kW
10 A
RCD 30mA
Controls
L3 N3
L5 N5
PE
N
HK2
oder
Kombi
IP 65
230 V~ 50 Hz
L
L
L
N
N
PE
PE

Publicidad

Tabla de contenido
loading

Tabla de contenido