Description
The EV-030 chain counter displays the length of chain let out or down, expressed in metres or feet and
the speed of the same.
Technical data
Power supply
Current intake
Protection rating of front cover
Operative temperature
Graphic display
Max. chain length
Size (mm)
Weight (g)
* excluding cable connection zone - ** without protective cover
Warning
CONNECT ONLY TO A DC POWER SUPPLY.
General notes
The EV-030 chain counter must be used solely for the purposes described herein, i.e. to operate and
display the number of metres/feet of chain let out by an anchor windlass. Any other use is to be
considered improper.
Any tampering with the instrument will result in immediate voiding of the warranty.
Components
The package contains:
•
chain counter, seal and closure cover;
•
10-pole male connector with crimp-type10 male contacts;
•
instructions for use.
Installation
On a few models of anchor windlass the sensor and the magnet are already installed (chain
counter setting). Therefore, the operations described below are not necessary.
Installing the magnet on the anchor windlass
•
A hole having a diameter of 6.5 mm (~1/4") and depth of 8 mm (5/16") must be drilled on a tooth
of the gipsy, in a place outside the chain's path.
•
In the case of vertical shaft anchor windlasses (see Fig. 1B), drill the hole in the lower
circumference of the gipsy.
•
In the case of horizontal shaft anchor windlasses (see Fig. 2B), drill the hole in the outer
circumference of the gipsy.
EV-030
17
English
from 10 to 30 V DC
min. 5 mA – max 40 mA
IP65*
0 / +70 °C (32 / 158 °F)
128 x 64 pixels
999 metres – 999 feet
100 x 100 x 32**
160
Rev. 13 – 2013