[012] Local PGM Output Pulse Activation Time
I_____I_____I
Minutes (00-99)
[021] First Keypad Options
Default
Opt.
ON
I_____I
1
Fire Key Enabled
ON
I_____I
2
Medical Key Enabled
ON
I_____I
3
Panic Key Enabled
ON
I_____I
4
Display Access Code When Pro-
gramming
[022] Second Keypad Options
Default
Opt.
ON
I_____I
1
Local Clock Display ON
OFF
I_____I
2
Local Clock Displays 24-hr
ON
I_____I
3 Auto Alarm Mem Scroll ON
ON
I_____I
4
For Future Use
OFF
I_____I
5
Power LED Enabled
ON
I_____I
6
Power LED Indicates AC Present ON
ON
I_____I
7 Alarms Displayed While Armed
OFF
I_____I
8 Auto-Scroll Open Zones ON
[023] Third Keypad Options
Default
Opt.
OFF
I____I
1 Armed LED Power Save
ON
I____I
2 Keypad Status Shows Stay Arm
OFF
I____I
3 5th Terminal is Keypad PGM Output 5th Terminal is Keypad Zone Input
OFF
I____I
7 Local Display of Temperature
Low Temperature Warning
OFF
I____I
8
Enabled
[030] Downloaded LCD Message
I _ ____I _ ____ I _ ____I _ ___ _I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ ____I _ _ ___I _ ____I _ ____I _ ____|
I _ ____I _ ____ I _ ____I _ ___ _I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ ____I _ _ ___I _ ____I _ ____I _ ____|
[031] Downloaded LCD Message Duration
Default: 000 I _____ I _____ I _____ I (Valid entries are 000-255, 000=Unlimited Msg Display)
This number represents the number of times the downloaded message must be cleared before it is
permanently removed. This message can be cleared by pressing any key.
[041] Indoor Temperature Zone Assignment
Default: 000
I_____I_____I_____I
I_____I_____I
Seconds (00-99)
ON
OFF
Fire Key Disabled
Medical Key Disabled
Panic Key Disabled
Display Xs When Program-
ming Access Codes
ON
Local Clock Display OFF
Clock Displays AM/PM
Auto Alarm Mem Scroll OFF
For Future Use
Power LED Disabled
Power LED Indicates AC Pres-
ent OFF
Alarms Not Displayed While
Armed
Auto-Scroll Open Zones OFF
ON
OFF
Armed LED Off in Sleep Mode
Keypad Status Shows Stay/Away
Arm
No Local Display of Temperature
Low Temperature Warning
Disabled
(Valid entries are 000-128)
[042] Outdoor Temperature Zone Assignment
Default: 000
[101]-[228] Door Chime for Zones 1-128
The keypad can be programmed to make up to four different chime sounds for individual zones.
(e.g., for Zone 1, enter section [101], for Zone 2 enter section [102]).
Default: 01 I_I_I
Valid Entries
01
02
03
04
05
[991] Reset Keypad Programming to Factory Defaults
1. Press [*][8][Installer Code].
OFF
2. Enter [991].
3. Use the [<][>] keys to scroll to the applicable keypad.
4. Press [*] to select the keypad.
5. Re-enter [Installer Code].
6. Press [*] to reset the selected keypad to factory defaults.
Table 3: Keypad Display Symbols
1
2
8
9
Memory – Indicates that alarms are in mem-
1
ory.
Fire – Indicates that fire alarms are in mem-
2
ory.
Clock Digits – These digits indicate the hour
and minutes when the local clock is active,
and also identify the zone when the OPEN or
3,4,
ALARM icons are active. These digits scroll
5
one zone per second from the lowest zone
number to the highest when scrolling through
zones.
1 to 8 – These numbers display toggles or dig-
6
its in binary while they are needed.
Bypass – Indicates that there are zones auto-
7
matically or manually bypassed.
Open – When zones are opened, this icon will
8
turn on and the open zones are displayed.
Program – If the system is in Installer's or
User's Programming, or the keypad is busy,
9
this icon flashes. If an access code is required
while accessing star menus, this LED is on
steadily to indicate that the code is required.
I_____I_____I_____I
6 beeps
Bing-Bing tone
Ding-Dong tone
Alarm tone (4 second duration)
Zone name
6
3
4
5
13
7
10
11
12
10 Chime – Turns on when Door Chime is ena-
11 Away – Indicates that the panel is armed in
12 Stay – Indicates that the panel is armed in
13
14 Ready Light (green) – If the Ready light is
15 Armed Light (red) – If the Armed light is
16 System Trouble – Indicates that a system
AC – Indicates that AC is present at the
17
(Valid entries are 000-128)
14
15
16
17
bled and off when Door Chime is disabled.
away mode.
stay mode.
Night – Indicates that the panel is armed in
night mode.
on, the system is ready for arming.
on, the system has been armed successfully.
trouble is active.
main panel.