DSC PowerSeries Neo HS2LED Instrucciones De Instalación página 8

Ocultar thumbs Ver también para PowerSeries Neo HS2LED:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Table 12: Wireless Device Placement Test Modes
Test each enrolled keypad
700
Test all keypads
701-716 for keypads 1-16
Two test results are provided:
• 24-hour: Average results of signal strength testing over a 24-hour period.
• Now: Signal status results of the current test.
During testing, the Ready and Armed LED's flash to indicate data is being received. A flashing
Trouble LED indicates RF interference. The following status indicators may be displayed:
Table 13: Wireless Device Status Indicators
LCD
Icon*
LED+
Status
Strong
1
9
Strong signal strength
Good
2
10
Good signal strength
Poor
3
11
Poor signal strength
The device is operating in 1-way
1-Way
4
12
mode only. The alarm panel cannot
configure or control the device
Displayed as the Now result if no
Not Test
5
13
test was performed.
Always displayed as the 24-hour
None
14
result when testing wireless keys.
NOTE:
For UL/ULC installations, only STRONG signal levels are acceptable.
*For Icon keypads, digit 1 indicates 24-hour test results; digit 2 indicates Now test results.
+For LED keypads, the first digit indicates 24-hour results; the second digit indicates Now test
results.
Troubleshooting
1. When attempting to assign a zone number to a wireless device, the keypad responds with a
long beep.
• Ensure that the keypad is properly connected to the Corbus.
2. After entering the ESN of a wireless device, then tripping it, the keypad does not indicate the
zone is open.
• Ensure the ESN has been entered correctly.
• Ensure that the zone is enabled for the partition (if partition programming is used).
• Ensure that the wireless zone is not assigned to a zone used by HSM2108 modules, an on-board
zone or a keypad zone.
• Ensure that the zone is programmed for something other than "Null Operation". "Poor" or no
results are received from a module placement test.
• Verify that you are testing the correct zone.
• Verify that the device is in range of the keypad. Try testing the device in the same room as the
receiver.
• Confirm that the keypad is properly connected to the Corbus.
• Check that the zone is being tested correctly. Refer to the instructions that came with the device.
• Check that the batteries are working and installed correctly.
• Look for large metal objects that may be preventing the signal from reaching the keypad.
• The device must be located where consistent "Good" results are obtained. If several devices
show "Poor" results, or if panic pendants and wireless keys operate inconsistently, move the
receiver.
NOTES:
Repeater [905]
Repeater 1
Repeater 2
Repeater 3
Repeater 4
Repeater 5
Repeater 6

Hide quick links: