Standard Outfit - Tecnomac AQUAMAC 100 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
1. WATER COOLERS MODELS 100 - 150 - 200
GENERAL INFORMATION
Models 100, 150 and 200 are water coolers with
stainless steel accumulation tank equipped
with expanded polyurethane foam condensa-
tion-proof insulation.
The water is refrigerated by means of an evap-
orator coil made of stainless steel.
The refrigeration circuit is generously sized and
equipped with a particularly robust condenser,
therefore guaranteeing excellent performance
even in conditions of high ambient tempera-
ture.
The refrigeration circuit is equipped with a ther-
mostatic expansion valve.
Water inlet is controlled by a solenoid valve and
the supply is interrupted when the tank is full by
means of a float/microswitch arrangement.
Uniform temperature of the water in the tank is
ensured by an agitator system for the 100 and
150 litre models and by a recirculator pump on
the 200 litre model.
A safety thermostat disconnects the appliance
when the temperature reaches + 1°, thus pre-
venting the formation of ice and the return of liq-
IMPORTANT
The following work is to be performed by the
client at its own expense and under its own
responsibility:
1) Provision of an electrical power circuit in
compliance with established legislation
(properly earthed, sized, etc.) with a dedi-
cated thermal-magnetic CB and rated in
accordance with the power absorption of the
uid to the compressor. Temperature control is
by means of high precision digital thermome-
ters-thermostats adjustable in 1 °C steps.
The version without pressure vessel is designed
for through-flow situations, while the version
with pressure vessel/pump is suitable for use
with a pressure head.
Power supply (100 and 150 litre models): single
phase 220V/50 Hz;
Power supply (300 litre model): 380V/3ph/50
Hz.
ACCESSORIES
1) Stand (For water coolers without pressure
2) Wall mounting bracket for 100 litre model

STANDARD OUTFIT

1) Water supply hose
2) Hose connector for outlet
3) Lever operated gate valve on water supply
2. INSTALLATION
W W
A A
R R
N N
W W
A A
R R
N N
THE FOLLOWING PROCEDURES
MUST BE PERFORMED
BY A LICENSED INSTALLER
2) Provision of water supply and drain connec-
3) a) Remove the packing material and the
vessel)
(see attached assembly instructions)
pipeline
I I
N N
G G
! !
I I
N N
G G
! !
plant. The electrical power feeding circuit
must incorporate a residual current circuit
breaker.
tion points as shown in figure A:
a) Water supply pipe with shut-off cock and
cartridge filter.
b) Drain outlet with stench trap.
material comprising the appliance outfit
GB
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aquamac 150Aquamac 200