Troubleshooting table
For spare parts and consumables, please use only genuine parts and designated products and components.
Using parts from other manufacturers or non-designated components may result in a malfunction.
Diagnosis
Chain oil does not come out.
Excessive vibration.
Consult your dealer in the event of a problem that is not covered in the table above, or other such concerns.
Please contact your dealer in order to dispose of the product or its parts in compliance with national laws.
Storage
Storage hook installation
Manufacturer:
YAMABIKO CORPORATION
1-7-2 Suehirocho, Ohme, Tokyo 198-8760 JAPAN
Authorized Representative in Europe:
Atlantic Bridge Limited
Atlantic House, PO Box 4800, Earley, Reading RG5 4GB, United Kingdom
Maintenance and care
5.
Finish cutter sharpening by rounding front raker edge (C)
with flat file.
6.
Properly filed cutter is as shown.
D: Top plate angle 30°
E: Top plate cutting angle 55°
F: Depth gauge 0.65 mm
G: Parallel
7.
Apply clean oil and rotate saw chain slowly to wash away fil-
ings.
8.
If saw chain is coated or clogged with resin, clean in kero-
sene, then soak in oil.
IMPORTANT
Cause
No oil in the oil tank.
Clogged chain oil pipe or oil fil-
ter.
Fault in the oil passage.
Warped or damaged cutting at-
tachment.
Loose gear case.
Bent drive shaft/worn or dam-
aged bushings.
1.
Insert small end of hook into locating hole on attachment
shaft.
2.
Slide plastic cap onto end of attachment shaft.
17
Solution
Fill the chain oil.
Clean the chain oil pipe and oil fil-
ter.
Consult your dealer.
Inspect and replace attachment as
required.
Tighten gear case securely.