CLEANING THE UNIT AND THE
REMOTE CONTROL
• Wipe them with a soft cloth.
• Do not directly splash or pour water on them. It
can cause electrical shock or equipment damage.
• Do not use hot water, thinner, abrasive powders or
strong solvents.
The open panel can be removed
REMOVAL
1
Push the release button and open the
lower part of the open panel.
2
Lift the open panel up slightly and re-
move it.
Open panel
ATTACHMENT
1
Hook both tabs on the shaft.
There is a shaft on each end of the unit.
2
Close the open panel.
Push the arrow-marked points on the open
panel until it clicks.
1
2
After attachment, be sure to close the open panel
fi rmly.
Unacceptable
Acceptable
Open panel
1
Release
button
2
Tab
Shaft
GB-13
MAINTENANCE AFTER AIR
CONDITIONER SEASON
1
Operate the unit in the SELF CLEAN
operation to allow the mechanism to
thoroughly dry.
2
Stop the operation and unplug the unit.
Turn off the circuit breaker, if you have
one exclusively for the air conditioner.
3
Clean the fi lters, then reinstall them.
MAINTENANCE BEFORE AIR
CONDITIONER SEASON
1
Make sure that the air fi lters are not
dirty.
2
Make sure that nothing obstructs the
air inlet or outlet.
CHANGING THE AIR PURIFYING
FILTER
The fi lters should be changed every 3 ~ 6 months
1
Remove the air fi lters.
2
Change the air purifying fi lters.
Take off the old air purifying fi lters from the
1
air fi lters.
Set the new air purifying fi lters, under the
2
fi lter stoppers located on the air fi lters.
3
Reinstall the air fi lters.
NOTE:
• The dirty air purifying fi lters are not washable
for reuse. The new fi lters are available at your
nearest dealer.
Replacement fi lter: Type AZ-F900F
Disposal of Filters
Please dispose of replaced fi lters according to the
local disposal laws and regulations.
AIR PURIFYING fi lter materials
Filter:Polypropylene
Frame:Polyester
Filter stopper