C7189U Remote Indoor Sensor
APPLICATION
This indoor sensor is designed to sense temperature
at a remote location and send this information to the
VisionPRO Thermostat. This sensor can be used as a
stand alone sensor or as part of an averaging
network. Once a remote indoor temperature sensor is
connected to the thermostat, the thermostat's sensor
is no longer used. The thermostat's installer setup
should be modified to tell the thermostat that remote
indoor temperature sensor(s) have been used. The
Inside temperature reading on the thermostat's
display will be the remote sensor(s) temperature
location(s).
Fig. 1. C7189U Remote Indoor Sensor
CAUTION
Electrical Interference (Noise) Hazard.
Can cause erratic system operation.
Keep wiring at least one foot away from large
inductive loads such as motors, line starters,
lighting ballasts and large power distribution
panels.
Use shielded cable to reduce interference
when rerouting is not possible.
M24055
INSTALLATION INSTRUCTIONS
SPECIFICATIONS
Operating Ambient Temperature Range:
45 to 88°F (7.2 to 32°C).
Display Range:
0 to 99°F (-18 to 37°C).
Sensor Accuracy:
+/-1.5°F at 70°F (+/-.84 at 21°C)
Operating Relative Humidity:
5% to 95% non-condensing.
Finish:
White.
Resistance Characteristics:
Negative temperature coefficient (NTC). Resistance
decreases as the temperature increases.
Dimensions in inches (mm):
1 1/2 (38) wide x 2 1/4 (57) high x 3/4 (19) deep.
Distance:
Maximum distance between thermostat and sensor is
200 feet.
Must be installed by a trained,
experienced technician
• Read these instructions carefully. Failure to follow
these instructions can damage the product or
cause a hazardous condition.
• Check the specification in this booklet to verify
that this product is suitable for the application.
• Always test for proper operation after installation
69-1710EFS-02

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Honeywell C7189U

  • Página 1 Maximum distance between thermostat and sensor is 200 feet. Must be installed by a trained, M24055 experienced technician Fig. 1. C7189U Remote Indoor Sensor • Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. CAUTION •...
  • Página 2: Installation Tips

    Can cause electrical shock or equipment damage. Disconnect power before beginning installation. 5 FEET (1.5 METERS) M24115 Fig. 2. Typical location for C7189U Sensor. Remote Sensor Wallplate Installation Remove the cover from the remote sensor as shown in Fig. 3. 1. Pull wires through wire hole.
  • Página 3 WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE. M19972A C7189 C7189 C7189 Fig. 6. Wiring a single C7189U Sensor. C7189 C7189 C7189 SENSORS MUST BE ARRANGED IN THIS CONFIGURATION TO OPERATE CORRECTLY. WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE.
  • Página 4: Room Temperature

    C7189U REMOTE INDOOR SENSOR CHECKOUT Table 1. Sensor Resistance at Room Temperature. For best results, allow the sensor to absorb the air Room Temperature Ohms of moving through the room for a minimum of twenty °F °C Resistance minutes before taking a resistance measurement.
  • Página 5: Caractéristiques Techniques

    Capteur de température ambiante à distance C7189U NOTICE D'INSTALLATION APPLICATION CARACTÉRISTIQUES TECHNIQUES Ce capteur de température ambiante sert à capter la température ailleurs qu'à l'emplacement du Gamme de température ambiante de service : thermostat et à transmettre l'information au 7,2 à 32 °C (45 à 88 °F).
  • Página 6: Conseils D'installation

    CAPTEUR DE TEMPÉRATURE AMBIANTE À DISTANCE C7189U INSTALLATION Conseils d'installation Installer le thermostat à environ 1,5 mètre (5 pieds) du sol dans un endroit où l'air circule bien et où la température est moyenne. La distance maximale entre le thermostat et le capteur est de 60 mètres (200 pieds).
  • Página 7 CAPTEUR DE TEMPÉRATURE AMBIANTE À DISTANCE C7189U CÂBLAGE Le capteur peut servir à procurer un relevé de la température à distance (voir la Fig. 6) ou une moyenne de la température ambiante s'il est utilisé en réseau avec d'autres capteurs, comme l'illustre la Fig. 7. Le thermostat ne fait pas partie du réseau de calcul de la température ambiante.
  • Página 8: Température Ambiante

    CAPTEUR DE TEMPÉRATURE AMBIANTE À DISTANCE C7189U Tableau 1. Résistance du capteur à la température CHANGE FILTER UV LAMP HUMIDIFIER PAD ambiante. Inside Set To AUTO Heat On Température ambiante Ohms de Following SYSTEM Schedule °C °F résistance HEAT 22537...
  • Página 9: Sensor Remoto Para Interiores

    200 pies. M24055 Este producto debe ser instalado por un técnico experto Fig. 1. Sensor remoto para interiores C7189U debidamente entrenado. PRECAUCIÓN • Lea cuidadosamente estas instrucciones. Si no sigue estas instrucciones, pueden producirse Riesgo de interferencia eléctrica (ruido).
  • Página 10: Consejos Para La Instalación

    5 FEET (1.5 METERS) M24115 Fig. 2. Ubicación típica para el sensor C7189U. Instalación de la placa para pared del sensor remoto Quite la cubierta del sensor remoto como se muestra en la Fig 3. 1. Pase los cables a través el agujero para cables.
  • Página 11: Funcionamiento

    CONSULTE LA FIGURA 7. LOS ALAMBRES DEBEN TENER UN CABLE POR SEPARADO DEL CABLE DEL TERMOSTATO. C7189 C7189 C7189 MS19972 Fig. 6. Cableado para un sensor C7189U independiente. C7189 C7189 C7189 LOS SENSORES DEBEN ACOMODARSE EN ESTA CONFIGURACIÓN PARA QUE OPEREN CORRECTAMENTE.
  • Página 12: Temperatura Ambiente

    SENSOR REMOTO PARA INTERIORES C7189U Tabla 1. Resistencia del sensor a temperatura CHANGE FILTER UV LAMP HUMIDIFIER PAD ambiente. Inside Set To AUTO Heat On Temperatura ambiente Ohmios de Following SYSTEM Schedule °F °C resistencia HEAT 22537 SCHED HOLD CLOCK SCREEN...

Tabla de contenido