RZ_FM 30_1018.qxp_Text_GB 30.10.18 15:01 Seite 21
NOTE
is no longer visible. The piston pressure gauge with integrated safety valve (K) gives information on
whether you are operating the unit at the optimum spraying pressure. The permissible operating
pressure of 3 bar may not be exceeded >>
Yellow marking:
You are working with the optimum spray pressure.
Red marking:
You are exceeding the maximum permissible operating pressure of 3 bar, the piston
gauge with integrated safety valve blows off the excess pressure.
NOTE
pump handle (A) by pushing the pump all the way down and slowly turning the pump handle (A)
clockwise until it stops. Now turn through the slight resistance until the pump is locked.
7
Shutting down
7.1 Emptying and cleaning >>
Solvents
Gasoline
Oil
safety instructions in this manual. Observe applicable laws and the specifications of the
agent manufacturers when disposing of residual quantities.
7.2 Storage >>
NOTE
and the foaming agents. You must therefore store the device and the foaming agents out of
the reach of children.
Empty and clean the device as in Chapter 7.1.
7.3 Maintenance >>
CAUTION
If foaming is no longer effective, check whether the air inlet bores in the suction nipple (M) are
clogged, clean them if required.
Observe the national regulations concerning occupational safety which apply to the place of
operation as well as the applicable national regulations for operations. An expert inspection must
be performed – ideally by the maintenance service of the manufacturer – to establish whether
hazard-free operation remains possible. This should be performed in the event of defects that
may impair safety in particular, and must be performed at least every 5 years in any case.
Only use original GLORIA spare parts for repairs.
(see GLORIA spare parts shop https://shop.gloriagarten.de).
Repairs must only be carried out by a GLORIA service point.
It is forbidden to perform repair work on the container (such as welding and soldering).
Further accessories can be found at www.gloriagarten.de.
Pump when the spray pressure decreases or the yellow marking on the piston gauge
>>
Figure
16
If the maximum operating pressure is exceeded, the piston gauge
with integrated safety valve (K) trips. Stop pressurising! Lock the
CAUTION
Health risk due to leaking foaming agent! Pay attention to the
figures
25
/
30
You may be exposed to hazards that could injure you when handling the device
figures
26
–
Figure
.
15
figures
17
–
24
29
21
21