Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
150 ±16 mm
cold right - hot left
max. 70°C / 4 min
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Maintenance (see page 32)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Dimensions (see page 34)

Flow diagram

(see page 35)
Shower outlet
Tub outlet
Spare parts
(see page 37)
XXX = Colors
000 = chrome plated
820 = brushed nickel
930 = Polished Brass
Operation (see page 39)
Cleaning
see enclosed brochure
Test certificate (see page 40)

Publicidad

Tabla de contenido
loading

Tabla de contenido