Tabla De Contenido; General Prescriptions; Safety Prescriptions; Installation Prescriptions - Comunello LIMIT 500 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
CONTENTS
1
1.1
1.2
1.3
2
MODELS AND PRODUCT DESCRIPTION
2.1
2.2
3
PRODUCT TECHNICAL SPECIFICATIONS
4
4.1
4.2
4.3
4.4
4.4.2 Limit stops adjustment
5
6
7
8
9
DISPOSAL OF THE PRODUCT
10
10.1
10.2
10.3
10.4

1 GENERAL PRESCRIPTIONS

1.1 SAFETY PRESCRIPTIONS

This installation manual is addressed exclusively to professionally skilled
personnel. Read all the instructions carefully before starting the installation
procedures. Any operations that are not expressly set down in these
instructions are to be considered prohibited; improper use may result
in damage to the product and place persons and property at risk. The
manufacturer declines all liability for failure to observe best technical practices
in barrier system construction and for any possible deformations that may
occur when using the product. Store this manual in a safe place for future
reference. The design and construction of the devices fitted on the LIMIT
model as well as this manual are in full compliance with statutory legislation.
In consideration of potential hazards that may arise during the installation
and use of LIMIT, also the installation procedures must be carried out in full
compliance with the applicable laws, standards and regulations; specifically:

1.2 INSTALLATION PRESCRIPTIONS

• Before starting the installation procedures make sure you have any
additional devices and materials that may be required to complete the
LIMIT barrier system in consideration of the specific application.
• The automation system must not be used until the transit area has been
made safe.
• Dispose of packaging materials in compliance with local regulations.

1.3 OPERATING PRESCRIPTIONS

• No modifications can be made to any part of the product unless
specified in this manual. Unauthorized modifications of the product are
likely to lead to malfunctions. The manufacturer declines all liability for
damage caused by unauthorized modifications.
• The parts of the automation system must never be immersed in water
or other liquids. During the installation procedures ensure that no solid
objects or liquids penetrate inside the control unit or other open devices.
• If liquids penetrate any parts of the automation system, disconnect the
electrical power supply immediately and consult technical service; the use
of LIMIT in such conditions may give rise to potentially hazardous situations.
• Keep all parts of the LIMIT barrier system away from heat sources and
open flames; exposure to heat or flames may damage the devices and
cause faults, fire, or hazardous situations.
• When the system remains unused for a long time, remove the
optional battery and store it in a dry place to avoid the risk of leakage
of harmful substances.
• Connect the control unit exclusively to an electric power supply line
equipped with an efficient protective earth conductor.
• Any operations that require parts of the LIMIT barrier system to be
opened must be performed with the control unit and the electrical
power supply disconnected; if the disconnect device is not clearly
visible from where you are working, attach a warning notice to the effect:
"WARNING - MAINTENANCE IN PROGRESS".
• In the case of tripping of circuit breakers or blowing of fuses, find the fault
and remedy it before resetting the circuit breaker or changing the fuse.
• If the fault cannot be remedied using the information given in this manual,
consult technical service.
2 MODELS AND PRODUCTS DESCRIPTION

2.1 DESCRIPTION

Sturdy and easy to install, the LIMIT electromechanical barrier system is
suitable for residential, public and industrial applications. Thanks to the
on-board electronic control unit any type of barrier system function can
be programmed.

2.2 TYPICAL INSTALLATION

D
E
B
KEY
A BARRIER SYSTEM WITH INTERNAL CONTROL UNIT
B PHOTOCELLS
C FLASHING LIGHT
D KEY SELECTOR SWITCH
E END REST
3 TECHNICAL SPECIFICATIONS
LIMIT 500
Operator power supply
Power consumption
Current input
Torque
100 Nm
Duty cycle
Protection rating
Insulation class
Working temperature
Weight
65 Kg

4 INSTALLATION

4.1 PRELIMINARY CHECKS

For correct operation of the automation system, make sure:
• all the accessories are suitably sized and properly maintained.
• all the operating limits of the product can be complied with.
• the minimum and maximum clearances shown in FIG. 1A, FIG. 1B and
FIG. 1C are complied with.
• all material used is in perfect condition and fit for purpose.
• the selected installation site is compatible with the overall dimensions of
the product.
• there are no hindrances that could obstruct the opening and closing
movements of the barrier arm.
• the footing of the barrier system is able to provide stable anchorage of
the unit.
• the space around the barrier system is sufficient to allow easy and safe
execution of manual barrier operations.
• all devices to be installed are in a protected location so as to minimize
the risk of accidental impact.
COMUNELLO ®Copyright 2014 - All right reserved
C
A
B
LIMIT 600
LIMIT 800
24 Vdc
150 W
6,5 A
300 Nm
Intensive
IP 24 D
1(earthing)
from -20°C to + 50°C
65 Kg
95 Kg
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Limit 600Limit 800

Tabla de contenido