ReguJap MaJflteflaflce
CHECK / LUBRICATE
FREE-HAND
LINKAGE
Check the function of the Free=Hand controls. The con-
trois should function as described in the CONTROLS
section. It is critical for the safe operation of the unit
that the controls disengage
when released.
Lubricate as shown in Figure 33.
IMPORTANT
NOTE
If the controls do not function properly, lubricate them.
If
lubrication does not rectify the problem, see your autho=
rized service dealer. Under no circumstances should the
unit be used if the controls are not functioning properly.
IMPORTANT
NOTE
It is very important that grease fittings on the auger shaft
are lubricated regularly. If auger rusts to the shaft, dam-
age to worm gear may occur if shear pins do not break.
LUBRICATE
AUGER SHAFT
ASSEMBLY
1. Remove cotter pin (C, Figure 34) and shear pin (B).
2. Use a grease gun and squirt several shots of grease
into grease fitting (A).
3. Rotate auger assembly (D) several times to distribute
the grease evenly. Repeat Step 2 for opposite side.
4. Reinstall shear pin (B) and cotter pin (C).
5. Repeat procedure for other side.
Lubricate Free-Hand Control
Figure 33
Lubricate Auger Shaft Assembly
Figure 34
27