Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
• As a standard, the wash basin mixer taps are supplied
with a jet forming device equipped with a regular
handspray stream. For an alternative jet design, an
aerator is enclosed that can easily be retrofitted on
site (see page 31 Fig. a1 - a2).
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
The product is exclusively designed for drinking water!
4
English
Symbol description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
Assembly see page 31
Do not use silicone containing acetic acid!
Dimensions (see page 32)
Flow diagram
(see page 32)
Regular Regular //
Normal spray Regular
Normal spray Booster
Regular Booster
Operation (see page 35)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Adjustable spout
For the version for right-handers, the spout
remains in the position as supplied to the
customer. For left-handers, the spout can be
turned by 80° to ensure perfect ergonomics.
Simply unscrew the jet forming device with
a suitable wrench and insert the spout in the
different position.
Spare parts (see page 34)
Cleaning (see page 33) and en-
closed brochure