UTILIZATION MANUAL
5. USING THE SPA
5.1. CONTROL PANEL OF THE SPA
Control components
Jets - Controls the massage of the water-air jets
Circ – Control the filtration circuit
Temp - Temperature control
Light - Light control
LCD Screen - Indicates temperatures and
messages
Led Heat - Heating indicator
This digital control panel is designed as a simple
operation control.
The minimum number of buttons and automatic
operation means that makes it simple and it can be
handled with hardly any effort.
RISK OF ELECTRIC DISCHARGE!
The user must not repair any parts. Do not
attempt to repair this control. Call your dealer
or maintenance staff for technical assistance.
If the electrical installation has been done properly,
once the Spa is connected, this will automatically
reach the "priming mode", the message "Pr" will
appear on the screen during 4 minutes while the auto
test is carried out. Afterwards, the Spa will start
heating the water.
All functions of the Spa will be operative after this test.
5.2. TEMPERATURE ADJUSTMENT (26º-40º C)
TEMP
Press
to adjust temperature. We will see the
real temperature of water on the screen unless we
press the button. When we press the button, we see
the programmed temperature on screen. If we press it
twice, the temperature will go up or down. Every time
that
we
press
the
temperature will change in the same direction.
If you wish to change the temperature direction,
release the button and wait until you see the real
button,
the
programmed
temperature of water on screen. Press again to see
the programmed temperature, and once again to
modify the programmed temperature in the wanted
direction. The programmable temperature range goes
from 26º to 40º C.
5.3. MASSAGE UTILIZATION
JETS
Press
twice to activate the massage Air-Water
circuit. Pressing this button the first time activates the
filtration circuit, which circulates and heats the water.
By pressing the second time the massage process
begins. After 15 minutes it will stop automatically. If
you wish to continue the massage, it is necessary to
press the button once again to have other 15 minutes
of massage.
5.4. JETS UTILIZATION
The water jets provide a hydrotherapy pressure jet. It
is a closed circuit, where the water is absorbed by
means of a pump through sumps and taken to the
jets.
The hydro massage effect is provided in the jet, when
the circuit water mixes with the outside air, in the so-
called Venturi effect.
To adjust the amount of air driven in the jets, simply
turn the tab of the air inputs (venturis) as follows:
Turn clockwise to reduce the amount of air mixed in
the jets. This will reduce the intensity of the jet.
Turn anti-clockwise to increase the amount of air
mixed in the jets. This will increase the intensity of the
jets.
MORE
INTENSITY
The jets can also adjust the flow intensity when
opening and closing the water. To do this, proceed as
follows:
Turn the outer ring a quarter clockwise to close the
jet.
OPEN
Turn the outer ring a quarter anti-clockwise to open
the jet.
6
EN
LESS
INTENSITY
CLOSE