Heatscope PURE Manual De Instrucciones página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
11. The power cable or buried cable with omnipolar switch may only be replaced by a profes-
sional specialist electrical company enlisted or approved by the manufacturer. Heating
elements, other components or parts of the housing may only be replaced by a service
organisation enlisted by the manufacturer. If you yourself or someone enlisted by you car-
ries out repairs, they will not be covered by the guarantee. Improper repairs and incorrect
installation or operation shall invalidate the guarantee immediately.
12. If the heater was installed inappropriately or was connected unhomogeneously with the
local electrical supply cable, high transfer resistances may occur, which lead to overhe-
ating of the device. If overheating of a carbon heating element occur due to interlinkage
EN
of mounting and installation mistakes, the carbon filaments inside of the quarz tubes will
fuse and safely disconnect the current flow. Even after a mechanical break of the quarz
tubes, the carbon heating spirals will not work any longer. Besides the glass ceramic,
high temperature resistant front screen of the heaters provide best protection of the
installed carbon heating elements. If a system malfunction inside the device causes
the shut down, the heater must be repaired by a professional technician; please contact
your dealer immediately. If a wrong cable connection causes the shut down, this has to
be checked and fixed through a professional electrician on the spot. Installation and con-
necting regulations with tested and approved luster terminals are part of the delivered
equipment.
13. The radiant heater must not be installed directly below a power source/socket. The sides
of the unit must be at least 20 cm from the nearest power source. Sockets/power sour-
ces must be freely accessible at all times and comply with the following specifications:
220–240 V AC ~, 50/60 Hz, 16 A with 16 A fuse. No other loads may be connected to
this power source.
14. The radiant heater must not be installed in rooms where there is high humidity (ba-
throom, spa, pool etc.) in close vicinity to bathtubes, showers or pools. The distance to
the bathtub or shower must be at least 100 cm and the distance to the pool at least 200
cm. A person standing in the bathtube, shower or pool should never reach the switch or
controller of the heater. If the HEATSCOPE
humidity, the switches or other operating components must be positioned in such a
way that they cannot be touched by persons who are in direct contact with water. When
a radiant heater is installed in a bathroom, the CE standard requires that at least one
heating element visibly „glows" as soon as the unit is switched on.
15. The heater must not be installed nor operated in environments containing chlorine (like
inside pool areas) or salt (like near the coast).
16. Disconnect the radiant heater from the power supply before cleaning it, adjusting the
angle or removing it from the wall/ceiling. Wait until the heating elements are not glowing
any more and the housing is noticably cooled down. If buried cables are used, switch off
the power using an omnipolar switch. Wait at least 30 minutes after the last use before
M U N I C H H O M E S Y S T E M S
MHS Munich Home Systems GmbH · Kramergasse 32 · 82054 Sauerlach · Germany
®
is installed in such an environment with high

Publicidad

Tabla de contenido
loading

Productos relacionados para Heatscope PURE

Tabla de contenido