Installation Place - MUNDO CLIMA MUCS 12 HF Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Four-Way Cassette Type

4. INSTALLATION PLACE

CAUTIONS
Location in the following places may cause
malfunction of the machine.(If unavoidable, please
consult your local dealer)
There is petrolatumexisting.
There is salty air surrounding (near the coast).
There is caustic gas (the sulfide, for example)
existing in the air (near a hot spring).
The Volt vibrates violently (in the factories).
In buses or cabinets.
In kitchen where it is full of oil gas.
There is strong electromagnetic wave existing.
There are inflammable materials or gas.
There is acid or alkaline liquid evaporating.
Other special conditions.
NOTICES BEFORE INSTALLATION
1. Select the correct carry-in path.
2. Move this unit as originally packaged as
possible.
3. If the air conditioner is installed on a metal part
of the building, it must be electrically insulated
according to the relevant standards to electrical
appliances.
1. The indoor unit
There is enough room for installation and
maintenance.
The ceiling is horizontal, and its structure can
endure the weight of the indoor unit.
The air outlet and the air inlet are not impeded,
and the influence of external air is the least.
The air flowcan reach throughout the room.
The connecting pipe and drainpipe could be
extracted out easily.
There is no direct radiation from heaters.
2. The outdoor unit
There is enough room for installation and
maintenance.
The air outlet and the air inlet are not impeded,
and can not be reached by strong wind.
It must be a dry and well ventilating place.
The support is flat and horizontal and can stand
the weight of the outdoor unit. And will no
additional noise or vibration.
Your neighborhood will not feel uncomfortable
with the noise or expelled air.
There is no leakage of combustible air.
It is easy to install the connecting pipe or cables.
Determine the air outlet direction where the
discharged air is not blocked.
A place free of a leakage of combustible gases.
In the case that the installation place is exposed
to a strong wind such as a seaside or high
position,
secure the normal fan operation by
putting the unit lengthwise along the wall or using
a duct or shield plates.
If possible, do not install the unit where it is
exposed to direct sunlight.
If necessary, install a blind that does not interfere
with the air flow.
During the heating mode, the water drained off
the outdoor unit ,The condensate should be well
drained away by the drain hole to an appropriate
place, so as not to interfere other people or public.
Select the position where it will not be subject to
snowdrifts, accumulation of leaves or other
seasonal debris. It is important that the air flow for
the outdoor unit is not impeded as this will result in
reduction in heating or cooling performance.
5
EN

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Mucs 18 hfMucs 24 hfMucs 30 hfMucs 36 hfMucs 48 hf

Tabla de contenido