11.TEST OPERATION

1. The test operation must be carried out after the
entire installation has been completed.
2. Please confirmthe following points before the test
operation:
The indoor unit and outdoor unit are installed
properly.
Tubing and wiring are correctly completed.
The refrigerant pipe systemis leakage-checked.
The drainage is unimpeded.
The heating insulation works well.
The ground wiring is connected correctly.
The length of the tubing and the added stow
capacity of the refrigerant have been recorded.
The power voltage fits the rated voltage of the air
conditioner.
There is no obstacle at the outlet and inlet of the
outdoor and indoor units.
The gas-side and liquid-side stop values are both
opened.
The air conditioner is pre-heated by turning on
the power.
3. According to the user's requirement, install the
remote controller frame where the remote
controller's signal can reach the indoor unit
smoothly.
4.Test operation
Set the air conditioner under the mode of
"COOLING" with the remote controller, and check
the following points per the "Owner's Manual". If
there is any malfunction, please resolve it as per
chapter "Troubles And Cause" in the "Owner's
Manual".
1)The indoor unit
a.
Whether the switch on the remote controller works
well.
b.
Whether the buttons on the remote controller
works well.
c.
Whether the air flow louver moves normally.
d.
Whether the roomtemperature is adjusted well.
e.
Whether the indicator lights normally.
f.
Whether the temporary buttons works well.
g.
Whether the drainage is normal.
h.
Whether there is vibration or abnormal noise
during operation.
i.
Whether the air conditioner heats well in the case
of the HEATING/COOLING type.
2)The outdoor unit
a.
Whether there is vibration or abnormal noise
during operation.
b.
Whether the generated wind, noise, or condensed
of by the air conditioner have influenced your
neighborhood.
c.
Whether any of the refrigerant is leaked.
CAUTION
Aprotection feature prevents the air conditioner from
being activated for approximately 3 minutes when it
is restarted immediately after shut off.
22
EN