Ecomat 3100
7
Components
1
Condensate drain line
2
Condensate inlet
3
Operating indicator (Power LED)
4
Test button
See fig. 1
8
Commissioning
Observe the safety instructions!
8.1
Installation
1. Connect one condensate drain line to
each Ecomat 3100 only to prevent the
condensate discharger from overloading
(fig. 3b).
2. Always use pressure-resistant installa-
tion materials!
3. Fixed installation of inlet line (G1/2")
with a minimum inclination of 1%
(fig. 3a).
During installation, place a spanner flat
on the inlet (size 27) and hold firmly in
position.
Install a ball valve (not included in the
scope of delivery) in the inlet line leading
to the Ecomat 3100.
4. Seal the threads on the connecting lines
properly using Teflon tape.
5. Turn
the
condensate
item 02) 90° depending on the operating
conditions. Slacken the two Allen screws
(fig. 7a, item 01) on the condensate in-
let.
6. Select a suitable air hose to use as a con-
densate drain line (min. inner diameter 9
mm). Secure the drain hose! Do not ap-
ply any bending forces to the Ecomat
3100!
7. Discharge the condensate into a suit-
able, sufficiently large container or oil-
water separator.
8. Insert the plug on the Ecomat 3100 into
a suitable 230 V 50 Hz power outlet. The
operating indicator (fig. 1a, item 03)
lights up.
8
8.2
• The mains voltage must match that speci-
• Electric protection according to technical
• Observe VDE regulations 0100 and 0105.
• The Ecomat 3100 is supplied with a con-
8.3
Please observe the following points
Recommended
cable sheath diam-
eter
Recommended
cable cross section
Electric protection
Recommendation
for stripping
cable sheath
Recommended
length of wire end
sleeves
Terminal connections
TER1.1
inlet
(fig. 1a,
TER1.2
TER1.3
1. Slacken screw (fig. 5a, item 01) and re-
2. Slacken the cable connection (fig. 5a,
3. Guide the power supply cable (fig. 5a,
4. Connect the cable to the terminals (fig.
5. Place the top section of the cover back in
6. Tighten the cable connection.
8.4
1. Carry out a visual inspection.
2. Check the electrical connection.
Electrical connection
fied on the rating plate.
data.
nection cable with power plug.
For
other
connection
Chap. 8.3.
Connecting the mains cable
dia. 5.8 – 8.5 mm
3 x 0.75 – 1.5 mm
0.5 A melting fuse
PE: L/N + 10 ... 50 mm
L/N: 50 ... 55 mm
approx. 6.0 mm
PE mains connection
N or L mains connection
L or N mains connection
move top section of cover (item 02).
item 04), remove the sealing stopper (if
available).
item 05) into position.
5a, item 03). Lay the cable as illustrated.
position and secure with the screw.
Before first use
options,
see
2