E-004
Motor connector error
Power [off]
E-008
The detector is abnormal.
Power [off]
E-009
The solenoid is abnormal.
Power [off]
E-010
The home position sensor is
abnormal. Power [off]
confirmation) of
panel)
E-011
The memory is abnormal.
Power [off]
E-020
The liquid crystal panel is
abnormal. Power [off]
E-025
Air pressure low Power [off]
E-026
[PMD]over current trip
Power [off]
*.Is the connector of the motor completely inserted?
*.Is not the signal of the connector of the motor disconnected?
[Message] MOTOR CONNECTER ERROR
*.Is the connector of the position detector firmly inserted?
*.Is not the signal of the position detector disconnected?
[Message] THE DETECTOR BREAKS OR THE SIGNAL CUTS.
*.Is not the signal of the position detector disconnected?
*.The solenoid is defective. (rolling wire defect)
[Message] THE SOLENOID BREAKS.
*.Does the wiring for the home position sensor Is disconnected or
it not short-circuited?
*.Is not the model mistaken?
[Message] STATE OF HOME SENSOR DOES NOT CHANGE.
*.Information could not saved correctly at the last power off
[Message] INFORMATION COULD NOT SAVED CORRECTLY AT
THE LAST POWER OFF
*. Does the wiring for the liquid crystal panel Is disconnected or
it not short-circuited?
[Message] LCD PANEL CONNECTION ERROR
*.Air pressure low detection input signal (ARS) has been input.
[Message] LESS PRESSURE
*.Is the stepping motor wiring broken(connection failure, short circuit)?
[Message] PMD OVER
*.Check the connector insertion.
*.Check the connector.
*.The connector is examined.
*.The signal is examined.
*.The connector is examined.
*.The signal is examined.
*.The wiring for the home position sensor is examined.
*.The model is examined.
*.Examines with (Home position/encoder /detector
input/output setting mode. (When connect the liquid crystal
*.Please install system software again.
*.The wiring for the liquid crystal panel is examined.
*.Turn [off] the power and remove failure portion.
*.Check the stepping motor wiring.
133