Installation And Assembly - Grasslin talis II PC 40-5-1i Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Switching capacity
Incandescent lamp load
Halogen lamp load (AC)
Halogen lamp load (LV)
Fluorescent lamp load
LED lamp / energy-
saving lamp

Installation and assembly

Packaging content and options
See Fig. 1
Dimensions
Fig. 2
Detector
Fig. 3
On-wall mounting with on-wall box talis
II SM BOX 20
Fig. 4
Suspended ceiling mounting with inter-
mediate unit talis II FC BOX 20
Location/installation (Fig. 5/6)
• Avoid installing the presence detector in the
vicinity of
− Source of heat (fan heaters, air-condition-
ing units, lighting etc.)
− Objects with reflective surfaces (mirrors
etc.)
− Objects that may be moved by the wind
• Avoid direct sunlight.
• The recommended installation height is
2.5 m.
Lens shield
You can shield off undesired areas of detection by
attaching the enclosed lens shield to the lens.
Use scissors to cut the lens shield horizontally or
vertically until you achieve the desired detection
range.
8
max. 2200 W
max. 2200 W
max. 1200 VA / 1000 W
max. 1200 VA / 140 μF
max. 800 VA / 600 W
Wiring diagram
Fig. 7
A connected load is controlled by a
presence detector.
LUX
Fig. 8
The connected load is switched on for
100
an adjustable period of time, either by
10
300
the presence detector or by the stair-
2000
case lighting time switch. The "TIME"
rotary knob must be set to
• If inductors are switched (e.g. relay, gate,
ballasts), it may be necessary to use a
quenching circuit.
• Parallel switching of a max. of 10 devices.
Installation
WARNING: Disconnect the voltage and secure it
against reconnection!
• Flush mounting
See Fig. 9/10 for the procedure
• Suspended ceiling mounting
with intermediate unit talis II FC BOX 20
See Fig. 11/12/13 for the procedure
• On-wall mounting
with on-wall box talis II SM BOX 20
See Fig. 14/15/16 for the procedure
Function test
• The sensor needs approx. 60 sec. starting
time.
• Switch the "TIME" rotary knob to "TEST" and
carry out the function test.
• Note the movement type (Fig. 6).
• The LED and the load are switched on for
3 sec. each time movement is detected and
switched off 2 sec. before the next detection.
• After the function test, stet the "TIME" rotary
knob to the desired value.
TIME
5m
15m
5s
30m
.
Test
1s

Publicidad

Tabla de contenido
loading

Tabla de contenido