5.
THE DEVICE OPERATION
Before turning on the device you must make sure that it has been properly installed and that its
technical condition allows safe exploitation.
•
Prior to operation, the control knob (Fig.8 Pos. 3) should be set to "0".
•
To switch on the appliance, turn the knob clockwise (the first (internal) heating area of the plate is
activated) and set the target temperature (min position - minimum power of the heating area, max po-
sition - maximum power). Switching on the first (internal) heating area will be signaled with an orange
indicator light (Fig. 8 Pos. 2).
•
To switch on the second (external) heating area of the plate, press the on/off button as in Fig.8 Pos.4.
Switching on the second (external) heating area will be signaled with an orange indicator light (Fig.8 Pos.
1). Pressing the button again will turn it off, the indicator light goes out.
•
To switch off the stove, set the knob to "0" counterclockwise (the indicator light goes off as in Fig.8
Pos. 2) and disconnect the power supply
1
Figure 8. Control elements of the device
ATTENTION!
You cannot relocate devices when:
•
The power cord is plugged in a socket,
•
The device's surface is not cooled,
•
There are some pots on the cooker
6.
CONSERVATION
Before starting any maintenance performances you must disconnect the device from power supply.
Everyday conservation consists of taking all plates off the device and washing the cooker elements
using a cloth moisturised with water with a dishwashing liquid, and then wiping them dry using a clean
cloth. Everyday you must check the condition of heaters, buttons, and switches on which there are seated
buttons. Detected devices eliminate heating panel and/or all device from exploitation – you must report
such defect to service.
Once per month you must check if:
•
Electrical connections are made correctly
•
The power cord has not been damaged
•
All elements of the device work properly.
Once per year you must service the device in order to check the level of its use and to detect potential
defects of elements and components.
In case of the detection of any failure you must submit it to a specialised technical service in order to get
some help in removing it.
Conservations are performed once per month, annual servicing and the device repairs can be carried out
only by qualified technical staff (technical service).
2
- 16 -
3
4
1. Signaling light for the external
heating area
2. Indicator light on the internal
heating area
3. Control knob
4. On/Off switch for external
heating area