English
3. Charging
When inserting a battery in the charger, the charge
indicator lamp will blink in blue.
When the battery becomes fully recharged, the charge
indicator lamp will light up in green. (See Table 1)
Before
charging
While
charging
Charge
indicator
lamp
(RED /
BLUE /
Charging
GREEN /
complete
PURPLE)
Overheat
standby
Charging
impossible
(2) Regarding the temperatures and charging time of the rechargeable battery
The temperatures and charging time will become as shown in Table 2.
Type of battery
Temperatures at which
the battery can be
recharged
Charging voltage
Battery
Charging time,
approx. (At 20°C)
Charging voltage
USB
Charging current
NOTE
The recharging time may vary according to the ambient
temperature and power source voltage.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger fi rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(RED)
Lights for 0.5 seconds. Does not light
Blinks
for 1 second. (off for 1 second)
(BLUE)
Lights for 1 second. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(BLUE)
Lights
Lights continuously
(BLUE)
Lights continuously
Lights
(GREEN)
(Continuous buzzer sound: about 6
seconds)
Lights for 0.3 seconds. Does not light
Blinks
for 0.3 seconds. (off for 0.3 seconds)
(RED)
Lights for 0.1 seconds. Does not light
for 0.1 seconds. (off for 0.1 seconds)
Flickers
(PURPLE)
(Intermittent buzzer sound: about 2
seconds)
Charger
V
14.4
BSL14.... series
(4 cells)
BSL1415S : 15
BSL1415 : 15
BSL1415X : 15
min.
BSL1420 : 20
BSL1425 : 25
BSL1430C : 30
V
A
(1) Charge indicator lamp indication
The indications of the charge indicator lamp will be
as shown in Table 1, according to the condition of the
charger or the rechargeable battery.
Table 1
Table 2
UC18YSL3
Li-ion
0°C – 50°C
BSL18.... series
(8 cells)
(5 cells)
BSL1815S : 15
BSL1430 : 20
BSL1815 : 15
BSL1440 : 26
BSL1815X : 15
BSL1450 : 32
BSL1820 : 20
BSL1460 : 38
BSL1825 : 25
BSL1830C : 30
5
2
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might be
low when using them the fi rst and second time. This is a
temporary phenomenon, and normal time required for
recharging will be restored by recharging the batteries
2 – 3 times.
12
Plugged into power source
Battery capacity at less than 50%
Battery capacity at less than 80%
Battery capacity at more than 80%
Battery overheated. Unable to
charge. (Charging will commence
when battery cools)
Malfunction in the battery or the
charger
18
(10 cells)
BSL1830 : 20
BSL1840 : 26
BSL36A18 : 32
BSL1850 : 32
BSL36B18 : 52
BSL1860 : 38
Multi volt
series
(10 cells)