SLV Elektronik GmbH
ENGLISH
INSTRUCTION MANUAL FOR
FITTING
MIBO Curve / MIBO Straight /
MIBO Wall Up-Down
1.
NOTES ON SAFETY
Installation, mounting or works on the electrical connection may
only be carried out by an approved electrician.
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no
decoration.
Keep children away from the product.
Operate the product only when it functions properly:
In case of a malfunction you may NOT touch the product or operate it
further. Disconnect the product from the power supply by an external
switch or by the fuse.
If touched or further operated there is danger from electric shock,
burning, or fire.
A malfunction exists when:
visible damages appear.
the product does not work properly (e.g. flickering).
smoke, steam or crackling sounds appear.
smell of burning is recognisable.
an overheating is recognisable (e.g. by discolouration of adjacent
surfaces).
Operate the product only after maintenance and examination by an
approved electrician!
2.
USE AS DIRECTED
This product serves exclusively lighting purposes and may:
only be used with a voltage of 230V ~50Hz.
only be operated when firmly mounted.
only be used indoors.
not be exposed to strong mechanical loads or to strong
contamination.
only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
not be modified or converted.
3.
OPERATION
Exchange the light source always before it reaches its lifespan, to avoid
personal injuries, or damages of the fixture or other objects.
Disconnect the product from the power supply, before you exchange
the bulbs. Let the light source cool down before replacement.
There exists danger of burning!
Use only light sources that are approved for the product. Approved light
sources are indicated on the type label.
Other types of light sources may cause fire risk, damage the product
or lead to malfunction.
Replacing the light source: Pull off the lamp glass by slightly turning it.
Use a piece of fabric to insert the bulbs. Do not touch them with bare
fingers. Carefully remove any fingerprints from the bulbs. Stick the bulb
into the socket. Fasten the outer lamp glass by turning it carefully.
4.
MAINTANANCE AND CARE
Disconnect the product from the power supply and let it cool down,
before you clean the product.
If disregarded there may be danger of electric shock or by burning
when cleaning the product.
Cleaning: Clean the product on a regular basis using a slightly
moistened, soft and fluff-free cloth.
5.
ADDITIONAL IMPORTANT NOTES
Storage: The product must be stored in a dry and clean environment. Do
not strain the product mechanically during storage.
Warranty: In case of a warranty contact your dealer.
Disposal: Notes on the correct disposal in Germany are found on
www.slv.de.
6.
INSTALLATION
(only by an approved electrician)
Switch off the mains or respectively the connection lead before doing
any works.
There exists mortal danger from an electric shock.
Use only parts, which are supplied with the product or are described as
accessories!
Otherwise the product or the whole installation may not be secure.
Danger for life or danger of fire may exist!
Inspect the product for loose parts inside the housing. When there are
loose parts inside the housing and these are not explicitly described the
product may not be installed or operated.
The housing maybe voltage-carrying. Danger of electric shock!
Use the supplied fastening material only when it is suited for the
installation background. If this is not the case use only fastening material
suiting the installation background.
When using fastening material that is not suitable there may be
danger from falling objects.
Unpacking
Consignment:
146390/92
Fastening materials
151282
Fastening materials
Three protective tubes
Carefully take the product out of the packaging removing any transport
safeguards.
Before disposal of the packaging material make sure that all
components of the product are removed.
Installation place
The product is solely suited for installation on a wall.
Make sure that the product is mounted on a stable, even and tilt-fixed
background.
Separate Installation Steps
146390/92: Fasten the lamp at the desired place utilizing the clamp.
Ensure a secure fixation.
151282: Remove the mounting bracket from the canopy by loosening
the two screws on the side of the canopy. Determine the place of
installation and mark the holes to be drilled. Note that the cable outlet of
the mains supply corresponds with the cable inlet of the fixture. Do not
damage the power supply line, e.g. by drilling, screws or strong bending.
Fasten the mounting bracket to the mounting surface.
Electrical Connection
146390/92: To maintain the protection class it is necessary to put
the clamp in a recessed installation box. The cable outlet must
be on the bottom.
Remove the cover on top of the connection clamp.
Loosen the strain relief. Direct the mains lead through the strain
relief.
The product must be able to be separated by an all pole separation
from the current supply.
151282: Equip the three wire ends with protective tubes.
For electric connection attach the black or brown wire (live conductor)
of the mains supply with the clamp L and the blue wire (neutral
conductor) of the mains supply with the clamp N. The green-yellow
wire (protective conductor) of the mains supply has to be tightly
screwed into the earth clamp
of the product.
146390/92: Put the cover back on the clamp. Secure the mains lead
with the strain relief.
151282: Now fasten the canopy back to the mounting bracket. Do not
forget to apply the toothed washers!
Inserting the light source: Use a piece of fabric to insert the bulbs. Do
not touch them with bare fingers. Carefully remove any fingerprints from
the bulbs. Stick the bulb into the socket. Fasten the outer lamp glass by
turning it carefully.
Check if the product functions properly and is securely fixed.
The product is now ready for operation.
art.-no. 146390/92 151282
©
01/2010
SLV Elektronik GmbH, Daimlerstr. 21-23, 52531 Übach-
Palenberg, Germany, Tel. +49 (0)2451 4833-0
Technical Details are subject to change.