ENGLISH
1. DESCRIPTION
The AERIA display cases are available in four different lengths and three different widths
a head case for the completion of back-to-back lines. The case is appropriate for preservation and self-service sale
of fresh and/or pre-packed products. Its main features and dimensions are clearly illustrated in drawings 1, 2, 3, on
page 3. As for its weights, crating included and excluded, see table I on page 4. A wide variety of optional accesso-
ries is also available for enhanced functions. To this respect, contact the authorised after-sales service only.
2. TRANSPORTATION
The display case is contained in a specially crated package that enables transportation by the use of fork lifts. Handle
the machine on its own pallet or on a similar platform; use a fork lift, either manual or electric, provided it is adequate
for handling such appliances and it has the requisite lifting capacity (see page 4 - fig. 4 and table I). Handling
is reserved for the authorised after-sales service.
3. DELIVERY AND STORAGE
Prior to accepting the case from the carrier, check the conditions of the package. If it is showing visible damage, the
machine may have suffered some consequences. If so, unpack the machine in the presence of the carrier and sign,
under protest, the delivery bill. The manufacturer assumes no liability for any damage caused by transportation or
wrong handling during storage. Unpacking is reserved for the authorised after-sales service. Storing temperatu-
re must be between -25°C and +55°C, air humidity between 30% and 95%. Keep the case safe from direct sunlight and
from the elements.
4. INSTALLATION AND AMBIENT CONDITIONS
The display case must not be installed in premises containing explosive gas substances. It can neither be
used in the open nor exposed to the rain.
Before connecting the case make sure that its rating plate data correspond to the features of the existing electri-
cal installation (see page 5 - fig. 8 and tab. III). For correct operation, the machine must be placed on a level
floor (see page 4 - fig 5), far from sources of heat and/or direct sunlight, d o o r s , w i n d o w s , f a n s o r v e n t i l a -
t i o n o u t l e t s (see page 4 - fig.6). It must also be granted a reasonable free front area for customer service.
The display case must be housed in a room conforming to the ambient requirements mentioned in page 4 -
fig. 7 and tab. II.
IMPORTANT: placing fixed panels on the top of the cabinet is advised against, as this part must be accessi-
ble for servicing purposes.
5. ELECTRICAL CONNECTION
IMPORTANT: ahead of the case there must be a MEANS FOR DISCONNECTION FROM THE SUPPLY MAINS HAVING
A CONTACT SEPARATION IN ALL POLES THAT PROVIDE FULL DISCONNECTION UNDER OVERVOLTAGE CATE-
GORY III CONDITIONS (see fig. 17). The position of the cut-out switch must enable its actuation in any EMER-
GENCY situation (maximum distance 3 m). Show the position of the cut-out switch to any prospective ope-
rator.
The refrigerator must be installed by professionally qualified personnel, in accordance with the
instructions provided by the manufacturer and local regulations. Incorrect installation may cause
harm to persons, animals andproperty. The manufacturer assumes no responsibility for such
damage.
20
. The range includes also