Unpacking the Device
• Remove the device from its packaging.
• Remove all of the packaging material such as foils,
filling material, cable holders and cardboard packaging.
• Check the scope of delivery.
NOTE:
There may still be dust or production residues on the
surface of the device. We recommend that you quickly
wipe of the housing with a damp cloth.
Assembly instructions
The appliance must be fully assembled before use! We
recommend that you refer to the figures "Overview" and
"Assembly overview" when assembling.
Base unit (Fig. a – c)
1. Screw the tubes (7) onto the stand (13). Use the four
screws (12), the metal plate (14), and the four nuts (15).
2. Attach the cover of the stand (16) to the stand tubes.
NOTE:
The nuts and screws (17) are preinstalled on the rear of
the switch housing.
3. Check if the screws (17) possibly have been screwed
into deeply. In this case, turn the screws back a little.
Do not screw them out all the way!
NOTE:
If a screw or a bolt should have dropped off, proceed
as follows:
• Hold the preassembled unit (motor (18), switch
housing (6), and humidifier base (10)) so that the
motor points down.
• Insert one nut (M6) each into the shaft at the
side of the recesses for the tubes.
• Screw the two screws (17) on the rear of the
switch housing lightly into the nuts.
4. Set the preassembled unit for a depth of approxi-
mately 3 cm onto the stand tubes.
NOTE:
The humidifier cable must be routed between the
two tubes.
Secure the preassembled unit to the stand tubes by
tightening the two screws (17).
5. Fasten the base of the humidifier (10)
with the large screw (ST4*25mm) to
the base of the stand. For this, insert
the screw from below through the
stand and its cover into the small
outer bore. (Fig. on the right)
Fan (Fig. d)
6. Remove the preinstalled nut (20) from the motor (18).
Keep it close to hand.
7. Align the rear protection grid (19) with the motor
recesses (18).
NOTE:
The handle must point upwards.
8. Tighten the nut (20) for the rear protection grid clock-
wise.
9. Attach the propeller (3). When doing so, use the guide
pin on the motor shaft.
10. Tighten the screw (21) for the propeller anti-clockwise.
11. Remove the prefitted screw and nut (5) from the front
protection grid (22). Keep it close to hand.
12. Open the fastening hooks (2) at the front protection
grid.
13. Attach the front protection grid by engaging the
groove of the hook (1) with the rear protection grid.
NOTE:
The holes for the screw (5) in the front and rear
protection grid must be aligned.
14. Secure the protection grid with the screw and the nut
(5).
15. Close the four fastening hooks (2).
Humidifier (Fig. e – f)
The tube already may have been installed on the switch
housing. In this case, continue the assembly from item 18.
16. Feed the tube (8) from front to back between the two
stand tubes (7). Then insert the tube from the bottom
upwards through the opening on the underside of the
switch housing (6).
NOTE:
The end of the tube with the tank cap must be
positioned at the front above the humidifier.
17. Insert the tube from the back to the front through the
opening on the top of the switch housing.
18. Pull the tube tight so that it lies flat against the back
of the switch housing.
NOTE:
The two ends of the tube should have approximately
the same length.
19. Connect the top end of the tube to the tube connec-
tor on the protection grid (22).
NOTE:
The tube above the switch housing must not "sag".
Water which accumulates in the tube prevents the
formation of the mist. If necessary, push back the
top section of the tube.
20. Place the water tank (9) onto the base of the humidi-
fier (10).