Kenmore 110.81422 Manual De Uso Y Cuidado, Instrucciones De Instalación página 14

Centro de lavandería de 24" (61 cm) de ancho. lavadora – secadora eléctrica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.
Connect neutral ground wire
and neutral wire
E
Remove center terminal block screw. Remove neutral ground
wire from external ground conductor screw. Connect neutral
ground wire and place the hooked end (hook facing right)
of the neutral wire (white or center wire) of direct wire cable
under the center screw of the terminal block. Squeeze hooked
ends together. Tighten screw.
A. Center terminal block screw
B. Neutral ground wire
C. External ground conductor screw – Dotted
line shows position of NEUTRAL ground
wire before being moved to center terminal
block screw.
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL listed strain relief
3.
Connect ground wire
A
F
Connect ground wire (green or bare) of direct wire cable
to external ground conductor screw. Tighten screw.
A. Neutral wire (white or center wire)
B. Center terminal block screw
C. Neutral ground wire
D. External ground conductor screw
E. Ground wire (green or bare) of direct
wire cable
F. 3/4" (19 mm) UL listed strain relief
14
A
B
C
D
B
C
E
D
4.
Connect remaining wires
Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws. Tighten strain
relief screw. Insert tab of terminal block cover into slot of dryer
rear panel. Secure cover with hold-down screw. Now go to
"Venting Requirements".
3-wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
1.
Prepare your 3-wire cable
for direct connection
Direct wire cable must have 5 ft. (1.52 m)
of extra length so Laundry Center can
be moved if needed.
Strip 3-1/2" (89 mm) of outer covering
from end of cable. Strip insulation back
1" (25 mm). If using 3-wire cable with
ground wire, cut bare wire even with
outer covering. Shape ends of wires into a hook shape.
When connecting to the terminal block, place the hooked end
of the wire under the screw of the terminal block (hook facing
right), squeeze hooked end together, and tighten screw. See
example above.

Publicidad