TROUBLESHOOTING

TROUBLESHOOTING

Before You Call

If you have any problems with the operation of your air
compressor, please call the air compressor helpline at
1-800-743-4115. If calling for assistance, please have the
model, revision, and serial number information printed on the
data tag available. (see Figure 22).
PROBLEM
Excessive tank pressure - Safety
Valve pops off.
Air losses
Knocking noise
22
CAUSE
Pressure Switch does not shut off engine
when compressor reaches "cut-out"
pressure or "cut-off" setting too high.
1.
Quick Connect Fitting cracked or
loose.
2.
Check Valve seat dirty or damaged.
3.
Defective Pressure Release Valve.
4.
Defective air tank.
5.
Leaking seal.
6.
Damaged Pressure Control.
Safety Valve dirty or defective.
www.mymowerparts.com
Figure 22 - Data Tag Information
MODEL
REV NO
SERIAL NO
CORRECTION
Move engine ON/OFF Switch to OFF
position. Contact trained service technician.
1.
Tighten Quick Connect Fittings where
air can be heard escaping. Replace
fittings.
2.
Contact trained service technician.
3.
Contact trained service technician.
4.
Air tank must be replaced. DO NOT
REPAIR TANK.
5.
Contact trained service technician.
6.
Contact trained service technician.
Operate Safety Valve manually by pulling on
ring. If valve still leaks, have it replaced at an
authorized service center.