over standard pumps, with the resulting cost sav-
ings.
Backwash plus:
Backwash system which, thanks to a
specially developed cycle, increases
process
efficiency
cleaning time, drastically reducing the
amount of water used for efficient cleaning.
EFFECTIVENESS: reduction of backwash time and
improved filter-cleaning efficiency.
SAVINGS: a minimum of 25% water savings over
standard pumps.
2. HANDLING
It is supplied in suitable packaging to prevent it de-
teriorating during transport. Before unpacking the
product, check that the packaging has not suffered
damage or is misshapen.
Handle the product carefully, with the right
tools.
3. INSTALLATION
This equipment is designed for use indoors.
3.1. Pump installation.
WARNING: Follow the installation manual in-
structions for the standard pump.
3.2. Electrical connection
The electrical installation must have a multi-
ple separation system with a 3 mm contact
opening.
The system's protection will be based on a
differential switch (∆fn = 30 mA).
The equipment is supplied with a power cable with
plug.
Do not handle the equipment.
3.3 ControlSystem
ControlSystem installation
ControlSystem
ControlSystem
Fit the ControlSystem to the multiport filter valve
control. (See figure 1)
• Select a location as near as possible to the turn-
ing centre.
• Clean the surface with alcohol.
• Lift the protective stickers and plug the
ControlSystem into the chosen place.
• Secure the assembly by tightening the tape un-
derneath the control. Check that it is fixed
properly.
4. START-UP
4.1 Starting up the equipment.
Follow the installation manual instructions for the
pump to start it up properly.
4.2. Initial configuration
The first time you start it up you need to link
SilenPlus with ControlSystem (See figure 2)
while
shortening
4.2.1 Starting up the Evopool
Connect the SilenPlus pump to the power supply.
The system will start up and a set of lights indicates
that it has been activated.
If a ControlSystem has not already been linked to it,
the pump will not start up.
SilenPlus is on standby waiting for the link to be
established. The 3 LEDs flash together.
4.2.2 Activating and calibrating the ControlSystem
To prevent the battery running out before the
equipment is started up, the ControlSystem has an
internal ON/OFF switch.
• Make
• Lift the cover, loosening the screw. (See figure 1)
• Activate the ControlSystem by moving the mini-
• Replace the cover and fix it with the screw.
When the battery is connected, ControlSystem
transmits a unique code for an interference-free link.
Flashing LEDs indicate that proper communication
has been achieved.
The position of the valve at this point is calibrated
as the FILTRATION position.
The pump will start up in Remote FiltrationPlus
mode. The corresponding LED will come on.
4.3 Multiple system
In an installation with several pieces of equipment,
SilenPlus must be started up and the ControlSystem
activated in order.
Each piece of equipment is linked using a unique
code to prevent interference between them.
A SilenPlus in standby mode will be linked to the
first ControlSystem activated.
4.4 In the absence of ControlSystem
If you do not have ControlSystem or prefer not to
use it, the system can work just as well manually.
Ignore the activation and calibration operations,
switch to Manual mode and then connect the
SilenPlus.
9
WARNING It is very important to follow the
order of the operations described here:
sure
the
valve
1 = FILTRATION.
switch to the "ON" position.
Torque: 0.2 Nm.
WARNING: activate the ControlSystem of the
valve for the equipment on standby.
EN
is
in
position