Charge battery in temperatures above 32°F (0°C) and below 113°F (45°C). Store ROSCOPE
i2000 in temperatures above -4°F (-20°C) and below 140°F (60°C). Storage for a long time
at temperatures above 95°F (35°C) will reduce the capacity of the ROSCOPE i2000. It is
recommended to store the ROSCOPE i2000 at 77°F (25°C) to maximize battery life. Proper
care will prevent serious damage to the battery. Improper care of the battery may result
battery leakage, electrical shock and burns.
If the ROSCOPE i2000 is damaged, do not plug the A/C power supply into it. Do not
attempt to charge.
Never use a home-made or incompatible battery pack. This may result in damage to unit
and/or cause injury.
Never disassemble the ROSCOPE i2000 unit. There are no user-serviceable parts inside.
Disassembling the ROSCOPE i2000 may cause electrical shock or personal injury.
Avoid contact with fluids leaking from the ROSCOPE i2000 unit. Fluids may cause burns or
skin irritation. Thoroughly rinse with water in case of accidental contact with fluid. Consult
doctor if fluid comes into contact with eyes.
Figure No. 1 - Power Supply
2

Technical Data / Specification

Viewable Distance ............... 5 cm – 30 cm (2" to 12")
A/C Power Supply ............ (See Figure No. 1 – Power Supply)
Internal Li-Ion Battery ..... 3.7V, 5200 mAh, 19.24 watt-hours
Weight ................................ 0.95 kilograms
Dimensions:
Length ................................ 35 cm (13.80")
Width .................................. 10.8 cm (4.25")
Height ................................. 7 cm (2.75")
Input voltage 100 - 240 VAC, 50 - 60 Hz, 0.3 Amp
Maximum inrush current 15 A @ 115 VAC, 30 A @ 230 VAC
5V DC 1.2 Amp Max Output voltage
No Load Standby power < 0.3 W
Operating Temperature 32°F to 104°F (0°C to 40°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Relative Humidity 20% to 80% non-condensing
The charger is supplied with a selection of adaptors for use in
multiple countries. Before first use, select the appropriate adaptor
for your country and attach it to the charger.
Estimated run time 3 - 5 hours* of continuous use (* actual battery
life will vary depending on the intensity of the Imager LEDs and the
usage of the Exterior Handheld Device Lights). Battery charge time
approximately 5 hours when units is turned off. (Note - Actual
charge time will be considerably longer if unit is turned on while
charging).