Digital Inputs - Oase WECS II 512 DMX/02 Instrucciones De Uso

Ocultar thumbs Ver también para WECS II 512 DMX/02:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- GB -
12

Digital inputs

The unit is equipped with eight configurable, galvanically isolated inputs for connection with third-party
systems or sensors.
The
input
voltage
(Low=-5V..5V, High= 11V..30V).
In addition that the digital input terminal (GND) must be activated (see figure).
Alternatively, the digital input 1 can be used to connect an OASE anemometer (No. 53913).
Wind speed measuring is useful for controlling the height of outdoor fountains used outside in relation to
the wind speed. In order to use the function the "speed"-canals of the pumps must be linked with the wind
fader in the WEPS-software. See also chapter 19.
32
range
for
the
digital
inputs
is
between
min.
-5V
and
30V
DC
Anemometer
53913

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wecs ii 1024 dmx/025649156492

Tabla de contenido