2.9

Troubleshooting

Observe the safety instructions and maintenance instructions!
Problem
A
No function is
apparent after pull-
ing the trigger lever
(item 02)
B
Grease gun dis-
penses too little
grease or none at
all
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
**See Chapter: "Intended use" in Instruction manual part 1!
****For troubleshooting: read chapter: "Commissioning"!
If necessary, contact our service staff, see last page.
II/ 10
Cause
Trigger lever (item 02) is
defective
No connection to compressed
air
No grease in grease reservoir
(item 05).
Seal in front housing defective
Grease piston is damaged
Cartridge inserted incorrectly
Grease too hard
Unsuitable material for the
device used
Grease reservoir not vented
Hose diameter too small
Compressor output too small
Working pressure (flow pres-
sure) too low
Remedy
Replace
the
*
(item 02)
Connect to compressed air
Add grease
Replace seal
Replace the grease reservoir
(item 05)
Reinsert cartridge
Heat up grease slightly
Use suitable material for the de-
**
vice
Actuate venting valve (item 03)
Use correct hose
*
diameter
Use different output
*
rating
Increase working pressure (flow
pressure)
Observe
working pressure
trigger
lever
***
***
maximum
*

Publicidad