Grohe RED MONO 30 080 Manual De Instalación página 14

Ocultar thumbs Ver también para RED MONO 30 080:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
• The boiling water storage heater is only suitable
for indoor use.
• The boiling water storage heater must be placed
in an upright position.
• The boiling water storage heater must not be
directly or indirectly sprayed with water when
cleaning.
• The boiling water storage heater must not be
opened.
• Use only genuine replacement parts and
accessories. The use of other parts will result in
voiding the warranty and the CE marking, and
could cause injury.
• Do not use a damaged device.
• The filter head must be replaced after 5 years by
the GROHE service.
• The use of extension cables is not permitted
between the electrical socket and boiling water
storage heater connection.
• The boiling water storage heater must be used
with the safety assembly supplied.
• To ensure uninterrupted function of the safety
assembly, it is advisable to have maintenance
work carried out regularly.
• The boiling water storage heater may only be
used with a GROHE Red fitting.
• Do not connect the hot water connection of the
fitting to the hot water outlet of the storage
heater. A mixing valve must be used (special
accessory *40 841), as necessary.
• If the operating pressure is insufficient, the
boiling water storage heater must be switched
off.
• In order to transport the boiling water storage
heater, it must first be emptied. To do this, the
safety assembly must be disconnected from the
boiling water storage heater.
Caution: risk of scalding. Escaping water is
boiling hot.
• No liability can be accepted for damage that
occurs due to non-observance of the operating
instructions.
13
Technical data boiling water storage heater:
• Connection:
• Installation elevation:
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative humidity:
• Ambient temperature:
• Standby power loss (switched on):
• Standby power loss (holiday mode):
• Standby power loss (switched off):
• Energy efficiency class:
Sanitary data:
• Boiling water storage heater capacity:
• Available storage heater volume at 100 °C:
• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
• Flow rate at 0.3 MPa flow pressure
- mixed water:
- boiling water:
• Boiling water temperature:
The actual temperature may differ slightly
due to different ambient pressures.
• Heating time from 10 °C to 100 °C:
• Clamping length of fitting:
• Water connection to storage heater:
• Water connection fitting:
The filter system with ion exchanger (S, M, L or Mg+) which is
included must be used in regions with a carbonate hardness
exceeding 10 °KH. The relevant water supplier can provide
information on the carbonate hardness.
Thermal disinfection of the fitting is possible.
Confirmation
Status
Storage heater LED Fitting LED
Initialisation
white
Heating phase
red, flashing
Ready for operation
red, continuous
Holiday mode,
orange, flashing
cooling-down phase
Holiday mode
orange, continuous
Child lock, unlocking
-
procedure
Child lock, unlocked -
Pot filling, unlocking
-
procedure
Pot filling
-
Defects
magenta,
flashing/continuous
wall socket with earth wire,
protected via a 10 A fuse
max. 2000 m above sea level
230 V AC / 50 Hz
max. 95 %
M: approx. 3 l
L: approx. 5.5 l
0.2–0.5 MPa
max. 0.8 MPa
approx. 6 l/min
approx. 3 l/min
M: approx. 20 min
L: approx. 30 min
max. 60 mm
cold water
cold/hot water from the service valve
boiling water from storage heater
-
-
-
-
-
red, flashing
red, continuous
yellow, flashing
yellow, continuous
magenta,
flashing/continuous
2200 W
IP X4
0–40 °C
M: 14 W
L: 15.7 W
M: 5 W
L: 7 W
1 W
A
M: 4 l
L: 7 l
0.2 MPa
1.6 MPa
100 °C

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Red mono 30 339Red mono 30 085

Tabla de contenido