F: When the 4-digit stops
blinking, the setting has
been locked to the indi-
cated value.
G: The required tem-
perature on the left, the
measured temperature
on the right.
4
56
Note: Some drops may leak from the tank. Put down the removable tank (cap
pointing upwards, handle on floor (Fig. C) and screw off the fuel cap.
3
Fill the removable tank using a fuel pump (refer to fuel pump operation instruc-
tions.) Make sure that it is in a higher position than the removable tank (Fig. D).
Insert the ribbed hose into the opening of the removable tank.
4
Check the removable tank fuel gauge while filling the tank (Fig. E). Stop filling
once the gauge indicates that the tank is full. Never overfill the tank, especially not
when the fuel is very cold (fuel expands when it heats up).
5
Let the remaining fuel in the pump flow back into the jerry can and carefully
remove the pump. Carefully screw the fuel cap back on the tank. Clean off any
spilled fuel.
6
Check whether the fuel cap is straight and tightened properly. Reinstall the remov-
able tank in the heater (cap down). Close the lid.
C
SETTING THE CLOCK
It is only possible to set the correct time, when the heater is connected to the mains
and not burning. Use the adjustment keys O to set the time. First press either of the
two keys to switch on the function (the 4-digit L will start blinking). Next, set the hours
using the key (Nhour) and the minutes using the key (Mmin.). Press once to increase the
value by one step. When you hold down the key, the value will continue going up, until
you release the key again. After approximately 10 seconds the 4-digit will stop blinking
and the setting will be locked. 5 minutes after switching off the heater, the information
on the display will disappear and the heater will automatically switch into the stand-by
position.
When the heater has been unplugged for more than 10 minutes (or after a power
failure), the time needs to be set again.
D
IGNITING THE HEATER
When used for the first time, a new heater may give out a smell for a short while. You
should therefore provide extra ventilation.
Always ignite the heater with the
Just press the
button M to ignite the heater.
The
button will start blinking, indicating that the ignition procedure has started. This
will take a short while. Once the heater is burning, the
The information display L will show two numbers (Fig. G). The actual room temperature
is indicated below ROOM, while the temperature setting is indicated below SET. The lat-
ter can be changed with the adjustment keys (refer to Section E).
Prior to igniting the heater, always check for sufficient fuel in the removable tank.
E
SETTING THE REQUIRED TEMPERATURE
The temperature setting can only be adjusted, when the heater is burning. Use the
adjustment keys O to adjust the temperature. First press either of the two keys to
switch on the function (the °C mark and 4-digit L will start blinking). Next, adjust the
temperature using the key (Mmin.) to set the temperature to a higher setting and the
key (Nhour) to lower the temperature. Press once to increase the value one step. After
approximately 10 seconds the °C mark and 4-digit will stop blinking and the setting will
be locked (Fig. F).
button M. Never use matches or a cigarette lighter.
button M will remain lit (red).