SPLAY BOLT
OPEN FACEPLATE
CONNECTION WIRING DIAGRAM (see figure on right)
TEST:
• Set the function switch to "ON", set "SENS" to maximum, "MIC" to maximum; "LUX" to maximum,
"TIME" to minimum.
• Switch on the power, the lamp should be on.
• Set the function switch to "OFF". After 30 sec the lamp should be off; all the functions should be in
the "stop" state.
• Set the function switch to "PIR". After 30 sec the inductor lamp will go on, after 20 sec when there is
inductor signal whether the lamp is on or not. Under no inductor signal condition, the lamp should
go off within 5~10 sec, and the lamp should go on again after 5 sec. Set "LUX" to minimum, after it
has gone off when there is no inductor signal condition, the lamp should be off during the daytime,
but if you use an opaque object to cover the sensor, the lamp should go on, then go off within
5~10 sec.
• Set the function switch to "+MIC", "LUX" to maximum, then when the sensor is in the infrared
detection +sound control mode, cover the detector. If the lamp is on, under the no inductor signal
condition, the lamp should go off after 5~10 sec. After 5 sec, if you clap your hands, the lamp should
go on, then off again after 5~10 sec (no inductor signal).
FIXED ARM
MOUNTING HOLE
3
Sensor switch