Page 32
7.3.8

Water Temperature Calibration

1.
Make sure the control is in the OFF mode.
2.
To enter the Service Setup mode, press and hold
the MENU, POOL and SPA button for 5 seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.
3.
This feature adjusts the heat pump water
temperature sensor. To select Water Temperature
Calibration, use the Up or Down button to scroll
through to display WATER TEMP CAL . Press the
MENU button. The 0°F (default mode) appears,
use the Up or Down button to scroll to display the
desired temperature adjustment, press the MENU
button to select. Press POOL or SPA to exit the
Service Setup mode.
7.3.9

Water Temperature Differential

1.
Make sure the control is in the OFF mode.
2.
To enter the Service Setup mode, press and hold
the MENU, POOL and SPA button for 5 seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.
3.
This feature sets the temperature differential the
heat pump will turn back on. To select Water
Temperature Differential, use the Up or Down
button to scroll through to display WATER
TEMP DIFF . Press the MENU button. The 3°F
(default mode) appears, use the Up or Down
button to scroll to display the desired temperature
adjustment, press the MENU button to select.
Press POOL or SPA to exit the Service Setup
mode.

7.3.10 Delay On Make

1.
Make sure the control is in the OFF mode.
2.
To enter the Service Setup mode, press and hold
the MENU, POOL and SPA button for 5 seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.
3.
This feature determines the amount of time the
heat pump waits before turning on the compressor.
To select Delay On Make, use the Up or Down
button to scroll through to display DELAY ON
MAKE . Press the MENU button. The 5 MINS
(default mode) appears, use the Up or Down
button to scroll to display the desired amount
of time, press the MENU button to select. The
remaining time is displayed while counting down.
Press POOL or SPA to exit the Service Setup
mode.