3.2

Control

Operating mode
Settings Level control
Settings Protection
01|2020
Under operating mode, the various
operating modes can be selected
manually.
Level control
Manual Feeding
Level control is the default setting. This is
shown with a tick in the selection menu.
The delay times, the water metering and
the fill-up time can be set in the Settings
Level control menu. A delay time between
2 seconds and 1 hour can be selected. The
quantity of water consumed per minute can
be be set under Water metering. This value
can be read on the water meter. The fill-up
time can be set under Time.
The safety time, the limit and an anti-
blocking protection can be set in the
Settings Protection menu.
The Fill-up safety time prevents the pool
from overflowing in the case of a sensor
error or permanent filling in case of too
great leakage. The power to Lp/Np is
switched off at the end of the safety time.
The maximum number of fillings is
controlled by Limit fill-up.
To prevent the solenoid valve from
blocking during long refilling periods,
voltage is applied to Lp/Np (or 11_14) to
switch the valve.