The residual current device is specified with 2 on the figure below. You may access the residual
current device by openin the lock which is placed on the side cover as shown in the figure below.
Place and push triangle key on the side cover lock then rotate the key 90 degree counter-clockwise.
Ensure that there are no faults on your vehicle or on the charging plug that may cause a residual
current before resetting the tripped residual current device.
After ensuring that there are no problems on your vehicle or on the charging plug, reactivate your
charging station by resetting the switch as shown in Fig. 3.
Reattempt to reset the switch by removing the charging plug. If the problem is continued, contact
an authorized service.
1

4.4 DC 6mA LEAKAGE CURRENT SENSOR BEHAVIOR

The charging station is equipped with a DC leakage current sensor that reacts a DC leakage current higher
than 6mA.
If the charging station goes to error state due to DC leakage current, AC power input shall be turned off to
reset the charging station from error state. See figure 3.4

LOSS OF MASTER RFID CARD

In case of loosing the registered Mastere RFID card, you can register a new Master card by following steps
below: