Extension Cord
WARNING: To reduce the risk of electric shock use only with an
extension cord intended for outdoor use, such as SW-A, S0W-A, STW-A,
STOW-A, SJW-A, SJOW-A, SJTW-A or SJTOW-A.
Make sure your extension cord is in good condition. When using an
extension cord be sure it is heavy enough to carry the current your product
will draw. An undersized extension cord will cause a drop in line voltage
resulting in loss of power and overheating. The following table shows the
correct size to use depending on cord length and nameplate ampere rating.
If in doubt, use the next heavier gage. The smaller the gage number, the
heavier the cord.
Minimum Gage for Cord Sets
Volts
Total Length of Cord in Feet
120V
0-25
240V
0-50
Ampere Rating
More Not more
Than Than
0
-
6
18
6
-
10
18
10 -
12
16
12 -
16
14
Double Insulation
Double insulated tools are constructed throughout with two
separate layers of electrical insulation or one double thickness
of insulation between you and the toolÅfs electrical system.
Tools built with this insulation system are not intended to be
grounded. As a result, your tool is equipped with a two prong
plug which permits you to use extension cords without concern
for maintaining a ground connection. NOTE: Double insulation does not
take the place of normal safety precautions when operating this tool. The
insulation system is for added protection against injury resulting from a
possible electrical insulation failure within the tool.
26-50
51-100 101-150
51-100 101-200 201-300
American Wire Gage
16
16
14
16
14
12
16
14
12
12
Not Recommended
REPLACEMENT PARTS: When servicing all tools, USE IDENTICAL
REPLACEMENT PARTS. Repair or replace damaged cords.
Polarized Plugs
To reduce the risk of electric shock, this equipment has a polarized plug
(one blade is wider than the other). This equipment must be used with a
suitable polarized 2 wire or 3 wire extension cord. Polarized connections
CAN/CSA-C22.2 NO. 60745-1-07 ♦ UL 60745-1
will fit together only one way. Make sure that the receptacle end of the
extension cord has large and small blade slot widths. If the plug does not fit
fully into the extension cord, reverse the plug. If it still does not fit, obtain a
suitable extension cord. If the extension cord does not fit fully into the outlet,
contact a qualified electrician to install the proper outlet. Do not change the
tool plug or extension cord in any way.
SYMBOLS
The label on your tool may include the following symbols.
The symbols and their definitions are as follows:
V ................ volts
Hz .............. hertz
min ............... minutes
or DC direct current
.............. Class I Construction
(grounded)
.............. Class II Construction
(double insulated)
.........................Read instruction manual before use
..........................Use proper respiratory protection
..........................Use proper eye protection
..........................Use proper hearing protection
SAVE THESE INSTRUCTIONS
6
CAN/CSA-C22.2 NO. 60745-1-07 ♦ UL 60745-1
JULY 31, 2007
A .......... amperes
W ......... watts
.alternating current
or AC
n o ........ no load speed
......... earthing terminal
....... safety alert symbol
.../min or rpm...revolutions or
reciprocation per minute