Troubleshooting
9
Troubleshooting
Problem
Cause
Roof air condi-
Icing sensor has tripped.
tioner constantly
switches itself off.
No cooling
The roof air conditioner is not set to
capacity
cooling.
The ambient temperature is above
52 °C.
The temperature set is higher that the
room temperature.
The ambient temperature is below
16 °C.
One of the temperature sensors is
defective.
The vaporiser fan is damaged.
The condenser fan is damaged.
Low air output
The air intake section is clogged up.
The blower is defective.
Water enters the
The condensation water drainage
vehicle
openings are clogged up.
The seals are damaged.
Roof air condi-
No supply voltage (230 Vw)
tioner does not
connected.
switch on.
The voltage is too low (under 200 V).
The voltage converter is defective.
One of the temperature sensors is
defective.
The electrical fuse of the power
supply is too low.
Roof air condi-
One of the temperature sensors is
tioner does not
defective.
switch off.
The electrical fuse of the power
supply is too low.
42
Dometic FreshJet
Remedy
Outer temperature is too low or all
air nozzles are closed.
➤ Set the roof air conditioner to
cooling.
The roof air conditioner is only
designed for ambient tempera-
tures of up to 52 °C.
➤ Select a lower temperature.
➤ The roof air conditioner is only
designed for ambient tempera-
ture above 16 °C.
➤ Contact an authorised work-
shop.
➤ Remove any leaves and other
dirt from the ventilation grilles
of the roof air conditioner.
➤ Contact an authorised work-
shop.
➤ Clean the drainage openings
for condensation water.
➤ Contact an authorised work-
shop.
➤ Check the power supply.
➤ Contact an authorised work-
shop.
➤ Check the electrical fuse of the
power supply.
➤ Contact an authorised work-
shop.
➤ Check the electrical fuse of the
power supply.
EN