NEVER LEA
NEVER LEA
NEVER LEA
•
The odorant in propane (LP) gas and natural gas is colorless and the
intensity of its odor can fade under some circumstances.
•
If there is an underground leak, the movement of gas through the soil can
filter out the odorant.
•
Propane (LP) gas odor may differ in intensity at different levels. Since
Propane (LP) gas is heavier than air, there may be more odor at lower levels.
•
Always be sensitive to the slightest gas odor. If you continue to detect
any gas odor, no matter how small, treat it as a serious leak. Immediately go
into action as discussed previously.
•
A periodic sniff test around the heater or at the heater's joints; i.e. hose,
connections, etc., is a good safety practice under any conditions. If you
smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER
IMMEDIATELY.
Operating Instructions
PREPARING FOR OPERATION
1.
Check the heater for possible shipping damage. If any is found, immediately
notify the factory.
2.
Follow all of the "Precautions".
3.
Connect the POL fitting of hose and regulator assembly to the propane
cylinder by rotating the POL nut counterclockwise into the propane
cylinder's valve outlet and securely tighten with a wrench.
4.
Connect the hose to the heater by rotating the hose fitting clockwise.
5.
Securely tighten all gas connections.
6.
Open the cylinder's gas valve and check all gas connections with a soap
and water solution. DO NOT USE A FLAME.
7.
Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of power.
8.
When using an extension cord, make certain that it is a 3-wire (grounded)
cord of proper wire size.
VE THE
VE THE HEA
VE THE HE
HEATER UNA
A
TER UNATTENDED WHILE BURNING!
TER UNA
START
1.
2.
3.
4.
5.
6.
7.
STOP
1.
2.
3.
RESTART AFTER SAFETY SHUTDOWN
1.
2.
3.
6
TTENDED WHILE BURNING!
TTENDED WHILE BURNING!
Before heater ignition, always allow heater fan (blower) to run for 20
seconds to purge fuel.
Slowly open the main valve at propane cylinder.
Depress the fuel valve button to light the heater.
After the heater lights, keep the gas valve button depressed for 15 seconds
then release and the heater will continue to operate.
Adjust burn rate by setting control knob to desired level.
Igniter continues to fire as long as power cord is plugged in.
No thermostat can be used with these units.
Securely close valve on the propane cylinder.
Continue to operate heater until all fuel in the hose has burned.
Unplug the power cord.
Securely close valve at propane cylinder. Unplug heater.
Wait 5 minutes.
Restart following "Start" procedure.