PRODUCT DATA SHEETS
Base
Grille Water
Filtration
System
Model WF-NLC240V/NLC240V
Capacity 240 Gallons (908 Liters)
Tested and certified by NSF international
against ANSI/NSF
Standard
42 for the reduction of Chlorine, Taste and Odor, Particulate Class I*;
and against ANSI/NSF Standard 53 for the reduction of Lead,
Mercury, Atrazine, Benzene, Toxaphene, p-dichlorobenzene,
2, 4-D,
Cysts, Turbidity and Asbestos.
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average % NSF Test
AeetheticEffects
Requirements
tnfluent
Concentration
Effluent
Effluent
Reduction
Reduction
Number
Chlorine Taste/Odor
->50%
2.0 mg/L
2.0 mg/L ± 10%
0.06 mg/L
0.05 mg/L
97.1%
97.5%
507173-02
Particulate Class I*
->85%
mL5'366'667/
At partleast
c es/mL10,000
4,100/mL**
2,300/mL
99.3%
99.9%
507175-02
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average % NSF Test
Reduction
Requirements
tnfluent
Concentration
Effluent
Effluent
Reduction
Reduction
Number
Lead: @ pH 6.5
0.01mg/L
0.16 mg/L***
0.15 mg/L ± 10%
0.001 mg/L
0.001 mg/L
99.35%
99.35%
507601-01
Lead: @ pH 8.5
0.01 mg/L
0.15 mg/L***
0.15 mg/L ± 10%
0.001 mg/L
0.001 mg/L
99.31%
99.31%
507602-01
Mercury: @ pH 6.5
0.002 mg/L
0.0061 mg/L
0.006 mg/L ± 10%
0.0004 mg/L
0.0002 mg/L
93.5%
96.7%
507603-02
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L ± 10%
0.0008 mg/L
0.00051 mg/L
85.8%
91.2%
507604-02
Benzene
O.0O5 mg/L
0.0138 mg/L
0.015±10%
0.O0O5 mg/L
0.0005 mg/L
96.3%
96.3%
507183-02
_-dichlorobenzene
0.075 mg/L
0.220 mg/L
0.225 ± 10%
0.0005 mg/L
0.0005 mg/L
99.7%
99.7%
507186-02
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 ± 10%
0.0014 mg/L
0.001 mg/L
90.0%
92.9%
507185-02
Atrazine
0.003 mg/L
0.009 mg/L
0.009 mg/L ± 10%
0.0013 mg/L
0.00036 mg/L
85.6%
95.9%
507181-02
2, 4-D
0.07 mg/L
0.197 mg/L
0.215 ± 10%
0.058 mg/L
0.0137 mg/L
70.6%
93.06%
507180-02
Asbestos
99%
26 x 10
10_to 10_fibers/L **** 0.18 x 10_ mg/[
0.18 x 107 mg/L
99.93%
99.93%
507178-02
Cysts .....
99.95%
111,000/mL
50,000/Lmin.
1 mg/L
1 mg/L
99.99%
99.99%
507187-02
Turbidity
0.5 NTU
11.08 NTU
11 ± 1 NTU
0.13 NTU
0.078 NTU
98.8%
99.3%
507751-02
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
•
It is essential that operational, maintenance, and filter
replacement
requirements be carried out for the product to
perform as advertised.
•
Model WF-NLC240V
Change cartridge at least every 6-9
months. Use replacement cartridge NLC240V, part #9908.
2003 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Prices are subject to change without notice.
•
The product is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected
waters that may contain filterable cysts.
•
Refer to the front cover or "Accessories"
section for the
Manufacturer's
name, address and telephone number.
•
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water
Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8 ° C)
Service
Flow Rate
0.5 gpm (1.9 Wmin.)
@ 60 psi.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL
of AC Fine Test Dust,
***These contaminants
are not necessarily in your water supply, Performance
may vary based on Ioca( water conditions.
.... Fibers greater than 10 um in length
*****Based
on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF international.