PERFORMANCE DATA SHEET
Base Grille Water Filtration
System
Model T1 KB2/T1 RFKB2 Capacity
200 Gallons (757 Liters) without
Filter Indicator
Light
System tested
and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the
reduction
of Lead, Mercury, Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity,
Asbestos,
Lindane,
Tetrachloroethylene,
Endrin, Alachlor,
Chlorobenzene
and Ethylbenzene.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances
listed below. The
concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the
permissible
limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Aesthetic Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Chlorine Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L + 10%
0.08 mg/L
**
2.0 mg/L
95.93
Particulate Class I*
85% reduction
3533333#/mL
At east 1O,OOOpart c es/mL
22000 #/mL
11567 #/mL
99.38
Contaminant
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Lead: @ pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L + 10%
1.0 ug/L
1 ug/L
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L + 10%
0.0002 mg/L
0.0002 mg/L
96.53
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
0.5 ug/L
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+ 10%
1.0 ug/L
1.0 ug/L
99.94
Toxaphene
0.003 mg/L
15 ug/L
Atrazine
0.003 mg/L
10 ug/L
Asbestos
99%
101 MFL
Live Cysts _
>99.95%
120,000/L
Turbidity
0.5 NTU
11.4 NTU
Alachlor
0.002 mg/L
41.3 ug/L
Endrin
0.002 mg/L
5.9 ug/L
Ethylbenzene
0.7 mg/L
1867 ug/L
Lindane
0.002 mg/L
1.9 ug/L
Chlorobenzene
0.6 mg/L
2.0 ug/L
Tetrachloroethylene
0.005 mg/L
14.2 ug/L
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Temp. = 68°F to 71.6°F (20°C to 22°C).
0.015 + 10%
0.009 mg/L _+10%
107to 108fibers/U t
50,000/L min.
11 _+1 NTU
0.04 _+10%
0.006 + 10%
2.1 _+10%
0.002 _+10%
2.0 _+10%
0.015 _+10%
1 .Oug/L
2 ug/L
0.17 MFL
8/U
0.41 NTU
0.2 ug/L
0.5 ug/L
0.70 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
1 .O ug/L
2 ug/L
0.17 MFL
1/ U
0.24 NTU
0.2 ug/L
0.3 ug/L
0.0588 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
93.33
80.8
99.83
99.99
96.4
99.52
91.5
99.96
98.93
99.98
96.47
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Average
%
Reduction
97.36
99.67
Average
%
Reduction
99.33
99.31
96.53
96.5
96.67
99.94
93.33
80.8
99.83
>99.99
97.89
99.52
95.47
100
98.93
99.98
96.47
•
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
•
Model
TIKB2:
Change the water filter cartridge
every 6 months.
If the water flow to the water dispenser
or ice maker decreases
noticeably
before 6 months
have passed,
replace the water filter
cartridge
more often.
Use replacement
cartridge
T1 RFKB2, part #9030.
In Canada, use
replacement
cartridge
T1 RFKB2, part #9030B.
2008 suggested
retail price of $44.99
U.S.A./S50.99
Canada.
Prices are subject to
change without
notice.
•
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
•
The product
is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown
quality
without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters
that may contain
filterable
cysts.
•
Refer to the front cover or "Accessories"
section
for the
Manufacturer's
name, address
and telephone
number.
•
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL
of AC Fine Test Dust.
ttFibers greater than 10 um in length
€Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark of NSF International.
23