3. 240 VOLT SINGLE PHASE OPERATION
The motor supplied with your machine is a dual
voltage, 120/240 volt motor. It is shipped ready-
to-run for 120 volt operation. However, it can be
converted for 240 volt operation.
A qualified electrician should do the conversion, or
the machine can be taken to an Authorized Delta
Service Center. When completed, the machine must
conform to the National Electric Code and all local
codes and ordinances.
The machine is converted by re-wiring the motor
for 240 volts, installing a 240 volt plug on the power
supply cord and replacing the switch with one that is
rated for 240 volt operation. (Delta P/N 438-01-017-
0141 needed for 240 volt operation.)
Be sure the 240 volt plug is only used in an outlet
having the same configuration as the plug illustrated
in Fig. C. No adapter should be used with the 240
volt plug.
In all cases, make certain that
the receptacle in question is properly grounded.
If you are not sure, have a qualified electrician
check the receptacle.
EXTENSION CORDS
Use proper extension cords. Make sure your extension cord is in good condition and is a 3-
wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the
machine's plug. When using an extension cord, be sure to use one heavy enough to carry the current of the
machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-
1 or D-2, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge.
The smaller the gauge number, the heavier the cord.
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Total
Length of
Ampere
Cord in
Rating
Volts
Feet
0-6
120
up to 25
0-6
120
25-50
0-6
120
50-100
0-6
120
100-150
6-10
120
up to 25
6-10
120
25-50
6-10
120
50-100
6-10
120
100-150
10-12
120
up to 25
10-12
120
25-50
10-12
120
50-100
10-12
120
100-150
12-16
120
up to 25
12-16
120
25-50
12-16
120
GREATER THAN 50 FEET NOT RECOMMENDED
Fig. D-1
Gauge of Extension
Cord
18 AWG
16 AWG
16 AWG
14 AWG
18 AWG
16 AWG
14 AWG
12 AWG
16 AWG
16 AWG
14 AWG
12 AWG
14 AWG
12 AWG
6 - English
GROUNDED OUTLET BOX
Fig. C
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Total
Length of
Ampere
Cord in
Rating
Volts
Feet
0-6
240
up to 50
0-6
240
50-100
0-6
240
100-200
0-6
240
200-300
6-10
240
up to 50
6-10
240
50-100
6-10
240
100-200
6-10
240
200-300
10-12
240
up to 50
10-12
240
50-100
10-12
240
100-200
10-12
240
200-300
12-16
240
up to 50
12-16
240
50-100
12-16
240
GREATER THAN 50 FEET NOT RECOMMENDED
Fig. D-2
Gauge of Extension
Cord
18 AWG
16 AWG
16 AWG
14 AWG
18 AWG
16 AWG
14 AWG
12 AWG
16 AWG
16 AWG
14 AWG
12 AWG
14 AWG
12 AWG