user interface

B1 = ON
Measurement and setting mode
Measurement range and accuracy:
The measurement range of the LRF 1700 is between 25°meters/27°yds and 1,700 meters/1,860 yds. In this respect,
the range depends on the weather conditions, the visibility and reflection characteristics of the target:
Range:
greater
Object colour:
white
Angle to the object:
perpendicular
Object size:
large
Atmospheric conditions:
clear, homogeneous
Object structure:
e.g. house wall
16
Press and hold
for approx. 3 seconds
Hold, target the object
and release
Press and hold
for approx. 4 seconds
smaller
black
acute
small
misty, inhomogeneous
e.g. bush, tree
In the event of sunshine and good visibility, the following ranges and accuracies apply:
± 1.0 m/yds up to 300 m/328 yds,
± 2.0 m/yds up to 600 m/656 yds,
± 0.5 % above 600 m/656 yds
Change from metres to yards
by pressing the B2 button. Saving and Auto OFF after 3 seconds
Individual measurement
Start a measurement in m/yds by pressing the B1 button
Scanning operation
Continuous measurements every 1.5 seconds
for a period of 20 seconds
B1
B2
en
Auto OFF after 5 seconds
Auto OFF after 20 seconds
The display shows „----" if:
- the distance is less than 25 meters
- the distance is more than 1,700 meters
- the reflection characteristics are insufficient
A low level of batteryis indicated by
a flashing display