Output terminals for connection of the auxiliary utility programmable
alternatively as:
ELECTRIC LOCK COMMAND
AUXILIARY FLASHING LIGHT
CAUTION: Maximum load 24V
1
2
3
4
5
6
7
8
O
N
DIP 7 ON = Auxiliary Flashing Light
DIP 7 OFF = Electric Lock Command
CAUTION: A variation to dip-switch settings requires a RESET via the key
on the control unit to apply the new settings.
LED STRIP SET-UP (manual mode)
1
2
3
4
5
6
LED STRIP ACTIVATION (LED):
The control unit enables the set-up of LED STRIP activation (optional), when
mounted on the bar, as always active (ON) or active only during operator
movement (off when operator is idle):
O
1
2
3
4
5
6
7
8
N
DIP 5 ON = LED Strip always ON
DIP 5 OFF = LED Strip only ON when operator is operating
1
2
3
4
5
ATTENZIONE: A variation to dip-switch settings requires a RESET via the
key on the control unit to apply the new settings.
LED STRIP MODE SETTING (LED MODE):
The control unit enables the user to set the operating mode of the LED
STRIP (optional), when fitted on the bar:
O
1
2
3
4
5
6
7
8
N
DIP 6 ON = Steady light
DIP 6 OFF = Flashing light
CAUTION: A variation to dip-switch settings requires a RESET via the key
on the control unit to apply the new settings.
ACTIVATION OF END LIMIT OVERRIDE:
The control unit enables the user to enable or disable operator thrust for
approx. 500ms over the limit switch activation (both in opening and closing
phases). This function enables the bar to be mechanically blocked more
securely in the open or closed position, reducing any possible oscillations.
O
1
2
3
4
5
6
7
8
N
DIP 1 OFF = End limit override disabled
DIP 1 ON = End limit override enabled (500ms)
CAUTION: A variation to dip-switch settings requires a RESET via the key
on the control unit to apply the new settings.
44
COMUNELLO ®Copyright 2015 - All right reserved
5W (continuous), 12W impulse
9
10
7
8
9
10
9
10
6
7
8
9
10
9
10
9
10
BUFFER BATTERY
The control unit enables connection of a buffer battery kit (code no. AC51),
which enables completion of a number of full manoeuvres at low speed in
emergency mode.
Input for connection of buffer battery kit.
CAUTION: Use only ONE buffer battery kits (code AC51)
CHANGING THE ROTATION DIRECTION OF THE OPERATOR
The control unit is equipped with a slide-switch which enables the setting or
modification of the direction of operator rotation.
Slide switch for controlling the rotation direction of the operator.
INV1
Operator 1 rotation inversion
CAUTION: A variation of the slide-switches requires pressing the
RESET button on the control unit to enable the new setting.
MASTER / SLAVE
The control unit can be set to operate in the modes MASTER or SLAVE.
This enables the connection, where required, of a SLAVE control unit to
the BUS accessory line, in the case of automations using barriers that are
set for synchronised operation (e.g. double barriers).
O
1
2
3
4
5
6
7
8
N
DIP 9 ON = Slave control unit
DIP 9 OFF = Master control unit
CAUTION: A variation to dip-switch settings requires a RESET via the key
on the control unit to apply the new settings.
CAUTION: In applications requiring the use of a single control unit, make
sure it is always set as MASTER. Otherwise, the automation will not work.
1
2
3
4
9
10
5
6
7
8
9
10