English
- Keep ventilation ports free from dust and
debris.
- Do not operate continuously for more than one
hour. Allow device to rest for 30 minutes before
re-using.
- Unplug the charger from device battery after
charging or prior to use.
- Do not use if injured. Consult your doctor
before using this product.
Usage instructions
Charging
- Fully charge battery for up to 3.5 hours before
first use either attached or detached from the
device.
- To charge, connect the DC end of the supplied
16.8v adaptor to the battery' s charging port
(Fig. C - C) and plug AC side cable into wall
outlet.
- LED band on battery lights pulsate to show
battery level and indicate active charging.
- With battery attached, LED lights on unit
flash to show battery level and indicate active
charging.
- Full charge is indicated when all LED lights stop
flashing and remain fully illuminated.
- Battery may be recharged at any time and at
any battery level.
- It is not recommended to fully deplete the
battery to the red LED level.
‼ NOTE
•
When the battery power is less than 20%,
the light line at the bottom of the machine
shows red.
•
When the battery power is less than 10%,
the power display window shows El,
indicating that it needs to be charged in
time.
⚠ WARNING
•
We strongly recommend to not operate the
machine during charging.
8
Operating
- Align and attach battery into base of unit-
ensure it is securely locked in place, taking note
of the battery bulge. (Fig. C - B)
- Power device on by moving the power switch
on the bottom of the battery to the ON
position when being in OFF mode.
- Massage desired body part at the desired
speed applying pressure as needed.
- To remove the battery, lightly press the battery
release button (Fig C - A) with thumb. Firmly
pull downwards on the battery/ handle with the
other hand.
Button functions
Power Switch Fig� C - 1
Turn On/ Off the power of the machine by setting
the switch in desired position.
On/ Off button (Fig� C - G)
- In Off mode, press button once to start
massage function.
in On mode, press button once to stop
massage function.
+/ - Button (Fig� C - F&H)
Press + and - buttons to adjust machine speed.
‼ NOTE
•
If button not respond, you have reached
your minimum/ maximum speed.
M (Mode) (Fig� C - I )
Operate only when machine power switch in On
mode and massage function in Off mode.
Press M button to select requested program.
- P0 Program is manual mode. Use +/- button to
adjust intensity as you wish.
- P1 Program will keep looping,
Starting from level 1, 2 to 3
Each speed will run 3 seconds.
- P2 Program will keep looping,
Starting from level 7, 8, 9 to 10
Each speed will run 3 seconds.
- P3 Program will keep looping,
Starting from level 16, 17, 18, 19 to 20
Press On/ Off button to start massage program.